Literature DB >> 27977866

Effect of simulated pulpal blood flow rate on the rise in pulp chamber temperature during direct fabrication of exothermic provisional restorations.

R I Farah1.   

Abstract

AIM: To evaluate ex vivo the effect of several simulated pulpal blood flow rates on the change in pulp chamber temperature during direct fabrication of a provisional restoration using a polymethylmethacrylate (PMMA) resin.
METHODOLOGY: Fifteen noncarious human premolars were prepared for complete coverage restorations. A curved needle connected to a peristaltic pump simulated the pulp blood flow. Two K-type thermocouples connected to a digital thermometer were placed in the pulp chamber, and the assembly was placed in an incubator at 37 °C. Three provisional crowns were made for each specimen using no water flow (group 1), a 1-mL min-1 flow rate (group 2) and a 0.5-mL/min-1 flow rate (group 3). The pulp chamber temperature was recorded continuously during polymerization until the temperature increase peaked and started to decrease and reached the baseline temperature (37 °C). The temperature increase was measured for the three water flow conditions. Data were analysed statistically using descriptive statistics, repeated measures one-way analysis of variance (anova) with Greenhouse-Geisser correction and Bonferroni tests. The level of significance was set at P < 0.05.
RESULTS: All of the groups were associated with an increased pulp chamber temperature. Groups with flow rates at 1 and 0.5 mL min-1 had a significantly lower temperature rise when compared to the group without water flow (P < 0.001).
CONCLUSIONS: Direct fabrication of provisional restorations can cause a critical increase in pulp chamber temperature. However, in the presence of simulated pulpal blood flow rates of 1 or 0.5 mL min-1 , the increase in pulp chamber temperature did not exceed the critical threshold (5.6 °C).
© 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  exothermic reaction; provisional resins; pulp blood flow; thermal injury

Mesh:

Year:  2017        PMID: 27977866     DOI: 10.1111/iej.12735

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  1 in total

1.  Effects of Different Amine Activators on the Monomer Conversion, Biaxial Flexural Strength, and Color Stability of Experimental Provisional Dental Restorations.

Authors:  Chawal Padunglappisit; Siwanath Posaya-Anuwat; Varisara Sompoch; Poompat Piyawiwattanakoon; Piyaphong Panpisut
Journal:  Eur J Dent       Date:  2021-02-03
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.