Literature DB >> 27965499

Micromovement Evaluation of Original and Compatible Abutments at the Implant-abutment Interface.

Antoine Berberi1, Dagher Maroun2, Wasfi Kanj3, El Zoughbi Amine4, Aramouni Philippe4.   

Abstract

INTRODUCTION: Use of compatible abutments may increase micromovements between the abutments, and the inner part of the implant may increase the stress on marginal bone level. Also micromovement will change the volume of the inner space of the implant-abutment complex. The resulting pumping effect can transport even initially immobile microorganisms from the exterior to the interior and vice versa.
OBJECTIVES: The purpose of the study was to evaluate the mechanical comportment of OsseoSpeed™ Tx implants connected with original and compatible abutments in vitro under simulated clinical loading conditions.
MATERIALS AND METHODS: A total of 15 OsseoSpeed™ TX implants (4 × 11 mm) were used and divided into three groups (n = 5). Three types of abutments were used in the study; group I: Five original Ti Design™ abutments, group II: Five Natea™ abutments, and group III: Implanet™ abutments. Abutments used in groups II and III were all compatible with Astra Tech Implant System™. Implants were embedded into resin. Simulating the human masticatory cycle, the axial force vector was increased up to a defined maximum (25, 50, 75, 100, 125, 150, 175, and 200 N) and inclined 30° to the implant axis. A radiograph amplifier was used to convert the X-ray projection into a picture. The visual evaluation of the frames and the provided X-ray videos were evaluated for an existing microgap in width and length between the implant and the abutment.
RESULTS: An initial width gap was observed in groups II and III in four of the five samples with an average of 6.5 and 5 μm respectively. When the axial forces reach 75 N, only groups II and III demonstrated a gap width of 5.2 ± 3.63 and 4.8 ± 3.03 μm, and a gap length of 5.2 ± 3.63 and 94 ± 125.3 μm respectively. At 200 N, group I showed a gap width of 8.4 ± 1.67 μm and a gap length of 187.6 ± 43.6 μm, while groups II and III showed a gap width of 12.4 ± 3.29 and 22.8 ± 5.76 μm, and a gap length of 387.2 ± 84.36 and 641.2 ± 122.6 μm respectively.
CONCLUSION: Within the limitations of this study and under the parameters used and from the resulting data collected, we can presume that the use of compatible components leads to significant micromovement when compared with the use of original ones. CLINICAL SIGNIFICANCE: The use of compatible prosthetic components with original implants showed significant micromovements when compared with the use of abutment and implant from the same manufacturer. Clinically, the micromovements when associated with leakage leads to bone loss around the neck of the implant and later to peri-implantitis.

Entities:  

Keywords:  Compatible; Gap; Implant-abutment interface Micromovement.

Mesh:

Substances:

Year:  2016        PMID: 27965499     DOI: 10.5005/jp-journals-10024-1952

Source DB:  PubMed          Journal:  J Contemp Dent Pract        ISSN: 1526-3711


  5 in total

1.  A comparative biomechanical study of original and compatible titanium bases: evaluation of screw loosening and 3D-crown displacement following cyclic loading analysis.

Authors:  Rimantas Ožiūnas; Jurgina Sakalauskienė; Darius Jegelevičius; Gintaras Janužis
Journal:  J Adv Prosthodont       Date:  2022-04-27       Impact factor: 1.989

2.  Comparative Evaluation of Retentive Properties of Two Compatible Ball Attachments in Mandibular Implant-Retained Overdentures: An In Vitro Study.

Authors:  Maryam Memarian; Simindokht Zarrati; Sedigheh Karimi; Mehran Bahrami
Journal:  J Dent (Tehran)       Date:  2018-03

3.  Mechanical Outcomes, Microleakage, and Marginal Accuracy at the Implant-Abutment Interface of Original versus Nonoriginal Implant Abutments: A Systematic Review of In Vitro Studies.

Authors:  Marco Tallarico; Joseph Fiorellini; Yasushi Nakajima; Yuki Omori; Iida Takahisa; Luigi Canullo
Journal:  Biomed Res Int       Date:  2018-12-30       Impact factor: 3.411

4.  Periodontal Pathogen Adhesion, Cytotoxicity, and Surface Free Energy of Different Materials for an Implant Prosthesis Screw Access Hole.

Authors:  Hsin-Ying Lu; Jason Hou; Yuta Takahashi; Yukihiko Tamura; Shohei Kasugai; Shinji Kuroda; Hidemi Nakata
Journal:  Medicina (Kaunas)       Date:  2022-02-21       Impact factor: 2.430

5.  Marginal Bone Level Evaluation of Fixed Partial Dental Prostheses Using Preformed Stock versus CAD/CAM Customized Abutments.

Authors:  Hui-Ting Lin; Jerry Chin-Yi Lin; Eisner Salamanca; Odontuya Dorj; Yu-Hwa Pan; Yi-Fan Wu; Yung-Szu Hsu; Chih-Yuan Fang; Wei-Jen Chang
Journal:  J Pers Med       Date:  2022-06-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.