Hiroshi Fujimoto1,2, Takashi Suekane3, Katsuya Imanishi4, Satoshi Yukiwaki1, Hong Wei5, Kaori Nagayoshi1, Masayuki Yahiro1,2,6, Chihaya Adachi1,2,6,7,8.
Abstract
We evaluated the influence of impurities in the vacuum chamber used for the fabrication of organic light-emitting diodes on the lifetime of the fabricated devices and found a correlation between lifetime and the device fabrication time. The contact angle of theEntities:
Year: 2016 PMID: 27958304 PMCID: PMC5153845 DOI: 10.1038/srep38482
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1Initial characteristics and lifetime of Group I devices.
(a) The ηext and lifetime of the TADF devices made in separate batches numbered in chronological order. (b) Lifetime as a function of device fabrication time, which is the time from the beginning of the HAT-CN deposition until the end of the Al deposition. Values are all averaged for two to four devices per batch.
Initial characteristics and lifetime of the devices.
| Voltage | Current density | Peak wavelength | Contact angle (°) | LT90 | ||
|---|---|---|---|---|---|---|
| Group I | 5.10 ± 0.17 | 2.05 ± 0.13 | 14.7 ± 0.9 | 524.9 ± 2.2 | 19–25 | 76–173 |
| Group II | 5.02 ± 0.14 | 1.86 ± 0.08 | 16.1 ± 0.6 | 523.6 ± 2.2 | 10–18 | 378–652 |
a1000 cd/m2.
bLifetime: Time until drop of luminance to 90% of the initial of 1000 cd/m2.
Figure 2Effect of chamber cleaning on lifetime and vacuum environment.
Device lifetime (bars), contact angles of ITO substrate stored in the vacuum chamber for 30 min before deposition (circles), and partial pressures of water during deposition for the batches fabricated before cleaning (Before), after chamber cleaning and evacuation to high vacuum overnight (Cleaning I), and evacuated to high vacuum for an additional two days (Cleaning II).
Figure 3Molecular masses of impurities.
Histogram showing the distribution of molecular masses of the detected materials.
Figure 4Analysis of LC-MS data after chamber cleaning.
(a) Breakdown of the ion counts after cleaning as a percentage of those before cleaning for the detected materials. (b) Ratios of the ion counts before cleaning to those after cleaning for the identified impurities (see Supplementary Fig. S2).
Figure 5Effect of fabrication time on lifetime and vacuum environment.
(a) Dependence of the lifetime on the device fabrication time for the Group II devices when the waiting times before and after EML deposition were equally extended or shortened. Lifetime values of 12 of the batches were averaged for two to four devices each, while only a single lifetime was available for the other five batches. (b) Total ion count for impurities measured by LC-MS on Si wafers loaded with the devices during fabrication. (c) Impurity quantity measured by WTD-GC-MS for DOA (squares) and DOP (triangles).