Ocular Radiation Threshold Projection Based off of Fluoroscopy Time During ERCP.

Mrinal S Garg1, Pikul Patel1, Margaret Blackwood2, Satish Munigala3, Payal Thakkar4, James Field1, Dustin Wallace1, Satty Agarwal1, Elie Aoun1, Abhijit Kulkarni1, Manish Dhawan1, Katie Farah1, Shyam Thakkar1.   

Abstract

OBJECTIVES: Current international guidelines for ocular radiation exposure suggest a threshold of 20 millisieverts (mSv)/year. Although endoscopists wear lead aprons, use of protective eye wear is optional. This study was conducted to analyze the lens radiation exposure during endoscopic retrograde cholangiopancreatography (ERCP) for endoscopists to determine the time of fluoroscopy needed to warrant using lens protection during ERCP.
METHODS: ERCP patients were prospectively enrolled. Indications, interventions, fluoroscopy time, dose, and attending ± fellow involvement were recorded. Radiation exposure was collected from body dosimeters and dosimeters placed between the eyes. Cumulative radiation doses were obtained at study completion and averaged over the total fluoroscopy time to determine the mSv/hour exposure.
RESULTS: A total of 187 cases were included. Attendings and fellows wore lens dosimeters in 178 and 126 cases, respectively, and body dosimeters in 174 and 128 cases, respectively. Attendings and fellows wore lens dosimeters throughout 15.89 and 11.24 h of fluoroscopy, respectively. The cumulative radiation dose absorbed per lens dosimeters was 5.35 mSv for attendings and 2.55 mSv for fellows. The projected lens absorption by the body dosimeters was 19.03 mSv for attendings and 5.21 mSv for fellows. The hourly fluoroscopy lens exposure was 0.34 mSv/hour for attendings and 0.23 mSv/hour for fellows.
CONCLUSIONS: The amount of fluoroscopy hours needed to reach the currently suggested lens threshold limit (20 mSv/year) was 59.41 h for attendings and 88.17 h for fellows. Radioprotective eye wear should be worn by physicians with yearly fluoroscopy times in similarly structured practices that meet or exceed these thresholds.

Entities:  

Mesh:

Year:  2016        PMID: 27958287     DOI: 10.1038/ajg.2016.540

Source DB:  PubMed          Journal:  Am J Gastroenterol        ISSN: 0002-9270            Impact factor:   10.864


  6 in total

1.  Effects of a Brief Educational Program on Optimization of Fluoroscopy to Minimize Radiation Exposure During Endoscopic Retrograde Cholangiopancreatography.

Authors:  Monique T Barakat; Nirav C Thosani; Robert J Huang; Abhishek Choudhary; Rajan Kochar; Shivangi Kothari; Subhas Banerjee
Journal:  Clin Gastroenterol Hepatol       Date:  2017-08-10       Impact factor: 11.382

2.  Radiation Training, Radiation Protection, and Fluoroscopy Utilization Practices Among US Therapeutic Endoscopists.

Authors:  Saurabh Sethi; Monique T Barakat; Shai Friedland; Subhas Banerjee
Journal:  Dig Dis Sci       Date:  2019-03-25       Impact factor: 3.199

Review 3.  The emerging role of non-radiation endoscopic management of biliary tract disorders.

Authors:  Andrew Ofosu; Daryl Ramai; Tagore Sunkara; Douglas G Adler
Journal:  Ann Gastroenterol       Date:  2018-06-19

4.  The impact of face shields on the quality of gastrointestinal endoscopy during the COVID-19 pandemic.

Authors:  Jong Yoon Lee; Yeo Wool Kang; Myeongseok Koh; Dong Kyun Kim; Jin Seok Jang; Jong Hoon Lee
Journal:  BMC Gastroenterol       Date:  2022-01-29       Impact factor: 3.067

Review 5.  Occupation-associated health hazards for the gastroenterologist/endoscopist.

Authors:  Emmanuel Ofori; Daryl Ramai; Febin John; Madhavi Reddy; Vishal Ghevariya
Journal:  Ann Gastroenterol       Date:  2018-04-27

6.  The difference in ocular lens equivalent dose to ERCP personnel between prone and left lateral decubitus positions: a prospective randomized study.

Authors:  Phonthep Angsuwatcharakon; Worawarut Janjeurmat; Anchali Krisanachinda; Wiriyaporn Ridtitid; Pradermchai Kongkam; Rungsun Rerknimitr
Journal:  Endosc Int Open       Date:  2018-08-01