Literature DB >> 27957083

The Unique MediGuide Technology For CRT Lead Placement And Catheter Ablation.

Carlo Pappone1, Martina Boscolo Berto1, Vincenzo Santinelli1.   

Abstract

Electrophysiologic procedures such as catheter ablation and/or cardiac resynchronization therapy (CRT) are usually performed under fluoroscopic guidance alone. Currently, we are witnessing the birth of a new era in which many patients can be safely and effectively treated without the use of fluoroscopy. Using MediGuide technology continuous fluoroscopy is no longer required to ascertain the position of the device/catheter, which minimizes the radiation exposure for both the physician and patient, with a further benefit by minimal need for contrast agent. This novel system provides real time tracking of devices projected into live fluoroscopy or pre-recorded cine-angiography. MediGuide technology is an important step forward facilitating complex ablation procedures such as AF ablation and CRT implantation.

Entities:  

Year:  2014        PMID: 27957083      PMCID: PMC5135152          DOI: 10.4022/jafib.1072

Source DB:  PubMed          Journal:  J Atr Fibrillation        ISSN: 1941-6911


  7 in total

Review 1.  American College of Cardiology/Society for Cardiac Angiography and Interventions Clinical Expert Consensus Document on cardiac catheterization laboratory standards. A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents.

Authors:  T M Bashore; E R Bates; P B Berger; D A Clark; J T Cusma; G J Dehmer; M J Kern; W K Laskey; M P O'Laughlin; S Oesterle; J J Popma; R A O'Rourke; J Abrams; E R Bates; B R Brodie; P S Douglas; G Gregoratos; M A Hlatky; J S Hochman; S Kaul; C M Tracy; D D Waters; W L Winters
Journal:  J Am Coll Cardiol       Date:  2001-06-15       Impact factor: 24.094

2.  Ablation of atrial fibrillation using novel 4-dimensional catheter tracking within autoregistered left atrial angiograms.

Authors:  Sascha Rolf; Philipp Sommer; Thomas Gaspar; Silke John; Arash Arya; Gerhard Hindricks; Christopher Piorkowski
Journal:  Circ Arrhythm Electrophysiol       Date:  2012-07-07

3.  Nonfluoroscopic sensor-guided navigation of intracardiac electrophysiology catheters within prerecorded cine loops.

Authors:  Christopher Piorkowski; Gerhard Hindricks
Journal:  Circ Arrhythm Electrophysiol       Date:  2011-08

4.  Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation.

Authors:  Riccardo Cappato; Hugh Calkins; Shih-Ann Chen; Wyn Davies; Yoshito Iesaka; Jonathan Kalman; You-Ho Kim; George Klein; Andrea Natale; Douglas Packer; Allan Skanes; Federico Ambrogi; Elia Biganzoli
Journal:  Circ Arrhythm Electrophysiol       Date:  2009-12-07

5.  Non-fluoroscopic catheter visualization using MediGuide™ technology: experience from the first 600 procedures.

Authors:  P Sommer; S Richter; G Hindricks; S Rolf
Journal:  J Interv Card Electrophysiol       Date:  2014-01-16       Impact factor: 1.900

6.  MediGuide in supraventricular tachycardia: initial experience from a multicentre registry.

Authors:  Philipp Sommer; Christopher Piorkowski; Thomas Gaspar; Charlotte Eitel; Michael Derndorfer; Martin Martinek; Helmut Pürerfellner; Arash Arya; Gerhard Hindricks; Sascha Rolf
Journal:  Europace       Date:  2013-04-23       Impact factor: 5.214

7.  Initial experience in ablation of typical atrial flutter using a novel three-dimensional catheter tracking system.

Authors:  Philipp Sommer; Agnieszka Wojdyla-Hordynska; Sascha Rolf; Thomas Gaspar; Charlotte Eitel; Arash Arya; Gerhard Hindricks; Christopher Piorkowski
Journal:  Europace       Date:  2012-08-02       Impact factor: 5.214

  7 in total