Literature DB >> 27942518

Lost wire? Ultrasound can find it for you!

Faisal Siddiqui1, Santosh Nepal1, Susanti Ie1, Sameh Aziz1.   

Abstract

The use of ultrasound (US) in clinical practice is becoming increasingly popular. This unique case highlights the importance of this technology in management of a complication arising from a central line placement in an intensive care unit (ICU).

Keywords:  Central line; guidewire; ultrasound (US)

Year:  2016        PMID: 27942518      PMCID: PMC5124621          DOI: 10.21037/atm.2016.11.10

Source DB:  PubMed          Journal:  Ann Transl Med        ISSN: 2305-5839


  8 in total

1.  Guide wire as a cause of complete heart block in patients with preexisting left bundle branch block.

Authors:  N T Eissa; V Kvetan
Journal:  Anesthesiology       Date:  1990-10       Impact factor: 7.892

2.  Case report: managing a knotted Seldinger wire in the subclavian vein during central venous cannulation.

Authors:  Kamran Z Khan; Donald Graham; Agota Ermenyi; Woolagasen R Pillay
Journal:  Can J Anaesth       Date:  2007-05       Impact factor: 5.063

3.  The incidence of retained guidewires after central venous catheterization in a tertiary care center.

Authors:  Hesham R Omar; Collin Sprenker; Rachel Karlnoski; Devanand Mangar; Jordan Miller; Enrico M Camporesi
Journal:  Am J Emerg Med       Date:  2013-08-15       Impact factor: 2.469

4.  Fatal pericardial tamponade by a guide wire during jugular catheter insertion.

Authors:  F Cavatorta; S Campisi; F Fiorini
Journal:  Nephron       Date:  1998       Impact factor: 2.847

5.  Cardiac perforation by a guide wire during subclavian catheter insertion.

Authors:  P G Blake; R Uldall
Journal:  Int J Artif Organs       Date:  1989-02       Impact factor: 1.595

6.  Incidence of arrhythmia with central venous catheter insertion and exchange.

Authors:  R K Stuart; S A Shikora; P Akerman; J A Lowell; J K Baxter; C Apovian; C Champagne; A Jennings; M Keane-Ellison; B R Bistrian
Journal:  JPEN J Parenter Enteral Nutr       Date:  1990 Mar-Apr       Impact factor: 4.016

7.  Life-threatening hemothorax resulting from right brachiocephalic vein perforation during right internal jugular vein catheterization.

Authors:  Yasushi Innami; Tomoko Oyaizu; Takashi Ouchi; Naoji Umemura; Toshiya Koitabashi
Journal:  J Anesth       Date:  2009-02-22       Impact factor: 2.078

8.  A lost guidewire.

Authors:  Pralay Kumar Sarkar; Kamal Mubarak
Journal:  Indian J Crit Care Med       Date:  2014-07