| Literature DB >> 27941713 |
Shuangqi Cai1, Yanan Li1, Ke Wang1, Yanling Cen1, Huasong Lu1, Biying Dong1, Yiqiang Chen1, Jinliang Kong1.
Abstract
BACKGROUND An animal (Sprague-Dawley rat) model of Pseudomonas aeruginosa biofilm associated with chronic pulmonary infection in vivo was established and the effects of the biofilm on P. aeruginosa and its relationship to cytokines were investigated. MATERIAL AND METHODS Biofilm of P. aeruginosa in alginate beads and planktonic PA0725 were purified by anion-exchange chromatograph. Sprague-Dawley (SD) rats were immunized with the biofilm and then inhaled the same strain of P. aeruginosa. Anti-biofilm antibody titer was detected using the enzyme linked immunosorbent assay (ELISA) method. The cell count and differential count in the bronchoalveolar lavage fluid (BALF) were measured. The levels of cytokines (IL-17, IL-1β, MIP-2, and G-CSF) and tumor necrosis factor (TNF)-α in sera were also measured using an ELISA kit. RESULTS The sera anti-biofilm IgG antibody titer of immunized SD rats was increased significantly on the 5th and 8th days after inhalation. The IL-17 concentration was significantly higher on the 8th day after inhalation. The results indicated that when biofilm-pre-immunized rats were challenged with inhalation of PA0725 of P. aeruginosa, the biofilm acted as an antigen substance and mediated the antibody reaction of the antigen, which might cause serious airway inflammatory response and lung tissue injury. This effect may be related to IL-17. CONCLUSIONS P. aeruginosa biofilm protected the bacterium from antibiotics and might induce host immune damage in lung tissue and facilitate bacterium evading the host barrier.Entities:
Mesh:
Substances:
Year: 2016 PMID: 27941713 PMCID: PMC5156558 DOI: 10.12659/msm.898783
Source DB: PubMed Journal: Med Sci Monit ISSN: 1234-1010
Figure 1The anti-alginate antibody titer value in serum after inhalation of Pseudomonas aeruginosa (error bars were added).
Figure 2Cell counts and classification in BALF after inhalation of Pseudomonas aeruginosa (error bars were added).
Figure 3Cytokine concentrations in serum after inhalation of Pseudomonas aeruginosa (error bars were added).
Cell percentages of CD4+ and CD8+ and the ratio of CD4+/CD8+ for the immune group and the control group.
| Days | CD4+ % | CD8+ % | CD4+/CD8+ | |||
|---|---|---|---|---|---|---|
| Immune group | Control group | Immune group | Control group | Immune group | Control group | |
| Day 2 | 45.28±2.24 | 48±1.38 | 24.03±1.86 | 17±1.23 | 1.87±0.18 | 2.82±0.16 |
| Day 5 | 43.61±2.03 | 49±1.27 | 22.38±1.75 | 17±1.14 | 1.95±0.13 | 2.87±0.21 |
| Day 8 | 41.42±2.33 | 47±1.19 | 21.55±1.77 | 16±1.19 | 1.94±0.15 | 2.92±0.24 |