Open retromuscular mesh repair versus onlay technique of incisional hernia: A randomized controlled trial.

Zaza Demetrashvili1, Irakli Pipia2, David Loladze3, Tamar Metreveli4, Eka Ekaladze5, George Kenchadze6, Kakhi Khutsishvili7.   

Abstract

INTRODUCTION: The aim of this prospective randomized clinical study was to compare and analyze the results of two methods of treatment of incisional hernia: open retromuscular mesh repair and onlay technique.
METHODS: 180 patients who underwent open elective surgery for middle primary incisional hernia were randomized into two groups. The retomuscular mesh repair was used in the first group and the onlay technique - in the second group. Several preoperative and intraoperative factors, also wound complications (wound infection, hematoma, seroma) and hernia recurrence rate were determined and compared between the groups.
RESULTS: The operative time was significantly longer in the retromuscular group compared with the onlay group (P < 0.001). In the retromuscular group 17 (22.1%) wound complications were observed, in the onlay group-39 (50.0%) wound complications. The difference was statistically significance (P < 0.001). Seroma was the most frequent postoperative wound complication, ranging from 16.9% to 41.0% among the groups, respectively (P = 0.0013). No significantly difference has been found between groups by wound infection and hematoma. 2 (2.6%) case of hernia recurrence was marked in retromuscular group and 4 (5.1%) case of hernia recurrence - in onlay group. But there was no statistically significantly difference between the two groups.
CONCLUSION: Our research shows no significant difference in frequency of hernia recurrence between retromuscular mesh repair and onlay technique for treatment of incisional hernia. The usage of the retromuscular mesh repair is associated with significantly less wound complications than onlay technique. That can be considered as an advantage of retromuscular method, which makes it more preferential than onlay method.
Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Incisional hernia; Onlay technique; Recurrence; Retromuscular mesh repair; Wound complications

Mesh:

Year:  2016        PMID: 27940291     DOI: 10.1016/j.ijsu.2016.12.008

Source DB:  PubMed          Journal:  Int J Surg        ISSN: 1743-9159            Impact factor:   6.071


  10 in total

1.  Reply to Comment to: A modified Chevrel technique for ventral hernia repair: long-term results of a single centre cohort. Li, J., Zhang, W.

Authors:  E H H Mommers; J A Charbon
Journal:  Hernia       Date:  2018-03-21       Impact factor: 4.739

2.  Robotic-assisted onlay technique: new approach using anterior mesh positioning in ventral hernia repair-an easy way to spread robotic surgery.

Authors:  João Vicente Machado Grossi; Flavio Malcher Martins de Oliveira; Eduardo Parra-Davila; Conrad Ballecer; Leandro Totti Cavazzola
Journal:  J Robot Surg       Date:  2021-03-08

Review 3.  Association between surgical hernia repair techniques and the incidence of seroma: a systematic review and meta-analysis of randomized controlled trials.

Authors:  L Beckers Perletti; F Spoelders; Frederik Berrevoet
Journal:  Hernia       Date:  2021-11-13       Impact factor: 2.920

4.  Predictors of hernia recurrence after Rives-Stoppa repair in the treatment of incisional hernias: a retrospective cohort.

Authors:  José Bueno-Lledó; Antonio Torregrosa; Raquel Jiménez-Rosellón; Providencia García; Santiago Bonafé; José Iserte
Journal:  Surg Endosc       Date:  2018-11-19       Impact factor: 4.584

5.  Wide variation in surgical techniques to repair incisional hernias: a survey of practice patterns among general surgeons.

Authors:  Simon MacDonald; Paul M Johnson
Journal:  BMC Surg       Date:  2021-05-24       Impact factor: 2.102

6.  What Is the Current Knowledge About Sublay/Retro-Rectus Repair of Incisional Hernias?

Authors:  Ferdinand Köckerling; Christine Schug-Pass; Hubert Scheuerlein
Journal:  Front Surg       Date:  2018-08-13

7.  Onlay Technique in Incisional Hernia Repair-A Systematic Review.

Authors:  Ferdinand Köckerling
Journal:  Front Surg       Date:  2018-11-27

8.  Prospective, multicenter study of P4HB (Phasix™) mesh for hernia repair in cohort at risk for complications: 3-Year follow-up.

Authors:  John Scott Roth; Gary J Anthone; Don J Selzer; Benjamin K Poulose; Richard A Pierce; James G Bittner; William W Hope; Raymond M Dunn; Robert G Martindale; Matthew I Goldblatt; David B Earle; John R Romanelli; Gregory J Mancini; Jacob A Greenberg; John G Linn; Eduardo Parra-Davila; Bryan J Sandler; Corey R Deeken; Jasenka Verbarg; Jennifer L Salluzzo; Guy R Voeller
Journal:  Ann Med Surg (Lond)       Date:  2020-12-15

9.  Is the recurrence rate of incisional hernia is affected by mesh positioning?

Authors:  Rashid Ibrahim; Talal Alshehri; Sabry Abounozha
Journal:  Ann Med Surg (Lond)       Date:  2021-01-09

10.  A systematic review of outcome reporting in incisional hernia surgery.

Authors:  D Harji; C Thomas; S A Antoniou; H Chandraratan; B Griffiths; B T Henniford; L Horgan; F Köckerling; M López-Cano; L Massey; M Miserez; A Montgomery; F Muysoms; B K Poulose; W Reinpold; N Smart
Journal:  BJS Open       Date:  2021-03-05
  10 in total