Literature DB >> 27939226

Effectiveness of a Prehospital Wireless 12-Lead Electrocardiogram and Cardiac Catheterization Laboratory Activation for ST-Elevation Myocardial Infarction.

Alain Tanguay1, Eric Brassard2, Johann Lebon3, François Bégin4, Denise Hébert5, Jean-Michel Paradis6.   

Abstract

The aim of the study was to determine the prevalence of false-positive and inappropriate cardiac catheterization laboratory (CCL) activation in patients suspected with ST-elevation myocardial infarction (STEMI) diverted to a percutaneous coronary intervention (PCI) facility after paramedics wireless 12-lead electrocardiogram transmission to an emergency physician at an online medical control center. This retrospective study collected data from medical records of patients with suspected STEMI from 2006 to 2014. It included demographics, coronaropathic risk factors, cardiac biomarkers, time from the first medical contact to treatment, and final diagnosis. Primary outcome was the rate of false-positive and inappropriate CCL activation. As secondary outcomes, we compared patient characteristics between cases of appropriate and inappropriate CCL activation, and we assessed the presence of cardiac biomarkers, time from first medical contact to start of PCI, and final diagnosis. Overall, 673 patients with suspected STEMI were included in the analysis. A total of 640 patients (95%) had coronarography, of which 10% (62 of 640) did not have a culprit coronary artery (false positive). Angiography was canceled for 5% (33 of 673) of patients. The total false-positive and inappropriate CCL activation rate was 14% (95 of 673). Average time from the first medical contact to the start of PCI was 47 ± 18.1 minutes. Unwanted CCL activations were more likely to involve men aged >65 years and patients with a history of coronary artery disease. In conclusion, our system of transmitted prehospital electrocardiography and STEMI interpretation by emergency physicians at an online medical control center showed a total false-positive and inappropriate CCL activation rate of 14% over the 8-year study period.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27939226     DOI: 10.1016/j.amjcard.2016.10.042

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  2 in total

1.  Effect of Real-Time Physician Oversight of Prehospital STEMI Diagnosis on ECG-Inappropriate and False Positive Catheterization Laboratory Activation.

Authors:  Laurie-Anne Boivin-Proulx; Alexis Matteau; Christine Pacheco; Alexandra Bastiany; Samer Mansour; André Kokis; Éric Quan; François Gobeil; Brian J Potter
Journal:  CJC Open       Date:  2020-11-25

Review 2.  Continuum of Care for Acute Coronary Syndrome: Optimizing Treatment for ST-Elevation Myocardial Infarction and Non-St-Elevation Acute Coronary Syndrome.

Authors:  W Brian Gibler; Judy M Racadio; Amy L Hirsch; Todd W Roat
Journal:  Crit Pathw Cardiol       Date:  2018-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.