Literature DB >> 27938914

Early effects of continuous positive airway pressure in a rodent model of allergic rhinitis.

I Vilaseca1, E Lehrer-Coriat2, M Torres3, F Aguilar4, I Almendros5, B M Martínez-Vidal6, R Farré7, J M Montserrat8.   

Abstract

BACKGROUND: Continuous positive airway pressure (CPAP) is the most commonly used treatment in obstructive sleep apnea. In a previous rat model study, we demonstrated that nasal CPAP induces early rhinitis expressed by nasal neutrophil extravasation. Here we hypothesized that nasal CPAP would worsen nasal inflammation on a previously inflamed mucosa. The objective of this study was to evaluate the early nasal CPAP effects of allergic rhinitis (AR) in a rodent model.
METHODS: Twenty Sprague-Dawley rats were sensitized with intraperitoneal ovalbumin (OVA). Nasal inflammation was induced by the administration of intranasal OVA during consecutive days. The same procedure was performed in 20 control rats treated with saline solution. The allergic (AR) and non-allergic (NAR) rats were then randomized to nasal CPAP at 10 cm H2O for five hours or to sham CPAP. The degree of nasal inflammation was assessed by evaluating the percentage of neutrophils, eosinophils, basophils, and lymphocytes in the nasal mucosa. An unpaired Mann-Whitney test was used to analyze differences between groups.
RESULTS: The greatest inflammation was observed in the group of AR without CPAP (1.24% ± 0.94%), followed by NAR with CPAP (0.64% ± 0.30%), AR with CPAP (0.64% ± 0.40%), and NAR without CPAP (0.21% ± 0.29%).
CONCLUSIONS: Administration of nasal CPAP or allergy sensitization can produce, individually, neutrophil extravasation on the nasal mucosa of a rat model. The application of both stimuli is not responsible for increased inflammation. Therefore, this study suggests that rhinitis is not a major limitation for CPAP administration.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Allergic rhinitis; CPAP; CPAP-induced rhinitis; Nasal inflammation

Mesh:

Substances:

Year:  2016        PMID: 27938914     DOI: 10.1016/j.sleep.2016.09.016

Source DB:  PubMed          Journal:  Sleep Med        ISSN: 1389-9457            Impact factor:   3.492


  3 in total

1.  Effects of CPAP in patients with obstructive apnoea: is the presence of allergic rhinitis relevant?

Authors:  A Cisternas; F Aguilar; J M Montserrat; M Àvila; M Torres; A Iranzo; J Berenguer; I Vilaseca
Journal:  Sleep Breath       Date:  2017-05-10       Impact factor: 2.816

Review 2.  Nasal function and CPAP use in patients with obstructive sleep apnoea: a systematic review.

Authors:  Marina Brimioulle; Konstantinos Chaidas
Journal:  Sleep Breath       Date:  2021-09-02       Impact factor: 2.655

3.  Effect of continuous positive airway pressure on allergic rhinitis in patients with obstructive sleep apnea-hypopnea syndrome.

Authors:  Qintai Yang; Hui Li; Weijun Wu; Xuekun Huang; Bo Tu; Yukun Ma; Huiyi Deng; Meijiao Li; Hongfeng He; Can Li; Yongqi Yang
Journal:  Ther Clin Risk Manag       Date:  2018-08-24       Impact factor: 2.423

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.