Literature DB >> 27936321

Stability of a Transient Protein Complex in a Charged Aqueous Droplet with Variable pH.

Myong In Oh1, Styliani Consta1,2.   

Abstract

Electrospray ionization mass spectrometry (ESI-MS) has the potential to become a high-throughput robust experimental method for the detection of protein-protein equilibrium constants. Poorly understood processes that affect the stability of weak noncovalent protein complexes in the intervening droplet environment are a significant factor that precludes the advancement of the method. We use molecular dynamics to study the stability of a ubiquitin and ubiquitin-associated domain complex (RCSB PDB code 2MRO ) in an aqueous droplet with changing size and charge concentration. We present evidence that a weak protein complex changes conformation and may dissociate in shrinking droplets. Then, the droplets containing these dissociated proteins divide. Our findings suggest that in some cases ESI-MS does not measure the correct association constants. The study intends to stimulate research for systematic development of experimental protocols that stabilize weakly bound protein interfaces in droplets.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27936321     DOI: 10.1021/acs.jpclett.6b02319

Source DB:  PubMed          Journal:  J Phys Chem Lett        ISSN: 1948-7185            Impact factor:   6.475


  5 in total

1.  Addressing a Common Misconception: Ammonium Acetate as Neutral pH "Buffer" for Native Electrospray Mass Spectrometry.

Authors:  Lars Konermann
Journal:  J Am Soc Mass Spectrom       Date:  2017-07-14       Impact factor: 3.109

2.  Strengths and Weaknesses of Molecular Simulations of Electrosprayed Droplets.

Authors:  Styliani Consta; Myong In Oh; Victor Kwan; Anatoly Malevanets
Journal:  J Am Soc Mass Spectrom       Date:  2018-09-26       Impact factor: 3.109

3.  Stoichiometry of Nucleotide Binding to Proteasome AAA+ ATPase Hexamer Established by Native Mass Spectrometry.

Authors:  Yadong Yu; Haichuan Liu; Zanlin Yu; H Ewa Witkowska; Yifan Cheng
Journal:  Mol Cell Proteomics       Date:  2020-09-03       Impact factor: 5.911

4.  The Evolution of Electrospray Generated Droplets is Not Affected by Ionization Mode.

Authors:  Piia Liigand; Agnes Heering Suu; Karl Kaupmees; Ivo Leito; Marion Girod; Rodolphe Antoine; Anneli Kruve
Journal:  J Am Soc Mass Spectrom       Date:  2017-07-25       Impact factor: 3.109

5.  Ion Mobility Mass Spectrometry Uncovers the Impact of the Patterning of Oppositely Charged Residues on the Conformational Distributions of Intrinsically Disordered Proteins.

Authors:  Rebecca Beveridge; Lukasz G Migas; Rahul K Das; Rohit V Pappu; Richard W Kriwacki; Perdita E Barran
Journal:  J Am Chem Soc       Date:  2019-03-12       Impact factor: 15.419

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.