Literature DB >> 27934611

A multicentre European registry to evaluate the Direct Flow Medical transcatheter aortic valve system for the treatment of patients with severe aortic stenosis.

Christoph K Naber1, Stylianos A Pyxaras, Hüseyin Ince, Peter Frambach, Antonio Colombo, Christian Butter, Fernando Gatto, Ulrich Hink, Georg Nickenig, Giuseppe Bruschi, Guus Brueren, Didier Tchétché, Peter Den Heijer, Wolfgang Schillinger, Smita Scholtz, Jan Van der Heyden, Thierry Lefèvre, Martine Gilard, Karl-Heinz Kuck, Joachim Schofer, Dimitar Divchev, Helmut Baumgartner, Federico Asch, Daniel Wagner, Azeem Latib, Federico De Marco, Stephan Kische.   

Abstract

AIMS: Our aim was to assess the clinical outcomes of the Direct Flow Medical Transcatheter Aortic Valve System (DFM-TAVS), when used in routine clinical practice. METHODS AND
RESULTS: This is a prospective, open-label, multicentre, post-market registry of patients treated with DFM-TAVS according to approved commercial indications. Echocardiographic and angiographic data were evaluated by an independent core laboratory and adverse events were adjudicated and classified according to VARC-2 criteria by an independent clinical events committee. The primary endpoint was freedom from all-cause mortality at 30 days post procedure. Secondary endpoints included procedural, early safety and efficacy endpoints at 30 days. Two hundred and fifty patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) with the DFM-TAVS were enrolled in 21 European centres. The primary endpoint, freedom from all-cause mortality at 30 days, was met in 98% (245/250) of patients. Device success was 83.8%. Moderate or severe aortic regurgitation was reported in 3% of patients, and none/trace regurgitation in 73% of patients. Post-procedural permanent pacemaker implantation was performed in 30 patients (12.0%).
CONCLUSIONS: The DFM-TAVS was associated with good short-term outcomes in this real-world registry. The low pacemaker and aortic regurgitation rates confirm the advantages of this next-generation transcatheter heart valve (THV).

Entities:  

Mesh:

Year:  2016        PMID: 27934611     DOI: 10.4244/EIJ-D-15-00511

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  2 in total

Review 1.  Rate and Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation: Current Status.

Authors:  Eleonora Russo; Domenico R Potenza; Michela Casella; Raimondo Massaro; Giulio Russo; Maurizio Braccio; Antonio Dello Russo; Mauro Cassese
Journal:  Curr Cardiol Rev       Date:  2019

2.  Transcatheter Aortic Valve Replacement with Self-Expandable ACURATE neo as Compared to Balloon-Expandable SAPIEN 3 in Patients with Severe Aortic Stenosis: Meta-Analysis of Randomized and Propensity-Matched Studies.

Authors:  Mirosław Gozdek; Kamil Zieliński; Michał Pasierski; Matteo Matteucci; Dario Fina; Federica Jiritano; Paolo Meani; Giuseppe Maria Raffa; Pietro Giorgio Malvindi; Michele Pilato; Domenico Paparella; Artur Słomka; Jacek Kubica; Dariusz Jagielak; Roberto Lorusso; Piotr Suwalski; Mariusz Kowalewski
Journal:  J Clin Med       Date:  2020-02-01       Impact factor: 4.241

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.