Literature DB >> 27928099

Evaluation of the accuracy and precision of four intraoral scanners with 70% reduced inlay and four-unit bridge models of international standard.

Soo-Hyuk Uhm1, Jae-Hong Kim, Heng Bo Jiang, Chang-Woo Woo, Minho Chang, Kyoung-Nam Kim, Ji-Myung Bae, Seunghan Oh.   

Abstract

The aims of this study were to evaluate the feasibility of 70% reduced inlay and 4-unit bridge models of International Standard (ISO 12836) assessing the accuracy of laboratory scanners to measure the accuracy of intraoral scanner. Four intraoral scanners (CS3500, Trios, Omnicam, and Bluecam) and one laboratory scanner (Ceramill MAP400) were used in this study. The height, depth, length, and angle of the models were measured from thirty scanned stereolithography (STL) images. There were no statistically significant mean deviations in distance accuracy and precision values of scanned images, except the angulation values of the inlay and 4-unit bridge models. The relative errors of inlay model and 4-unit bridge models quantifying the accuracy and precision of obtained mean deviations were less than 0.023 and 0.021, respectively. Thus, inlay and 4-unit bridge models suggested by this study is expected to be feasible tools for testing intraoral scanners.

Mesh:

Year:  2016        PMID: 27928099     DOI: 10.4012/dmj.2016-064

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  8 in total

1.  Influence of Applied Liquid-Type Scanning-Aid Material on the Accuracy of the Scanned Image: An In Vitro Experiment.

Authors:  Hyun-Su Oh; Young-Jun Lim; Bongju Kim; Won Hyeon Kim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  Materials (Basel)       Date:  2020-04-27       Impact factor: 3.623

2.  Clinical Evaluation of Time Efficiency and Fit Accuracy of Lithium Disilicate Single Crowns between Conventional and Digital Impression.

Authors:  Ji-Su Park; Young-Jun Lim; Bongju Kim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  Materials (Basel)       Date:  2020-11-30       Impact factor: 3.623

3.  Effect of the volumetric dimensions of a complete arch on the accuracy of scanners.

Authors:  Min-Kyu Kim; KeunBaDa Son; Beom-Young Yu; Kyu-Bok Lee
Journal:  J Adv Prosthodont       Date:  2020-12-28       Impact factor: 1.904

4.  Evaluating the accuracy of three intraoral scanners using models containing different numbers of crown-prepared abutments.

Authors:  Ting Zhang; Ting Wei; Yawen Zhao; Mengyang Jiang; Xiaojie Yin; Huiqiang Sun
Journal:  J Dent Sci       Date:  2021-06-01       Impact factor: 2.080

5.  Effect of posterior span length on the trueness and precision of 3 intraoral digital scanners: A comparative 3-dimensional in vitro study.

Authors:  Mohamed Fattouh; Laila Mohamed Mohamed Kenawi; Hesham Fattouh
Journal:  Imaging Sci Dent       Date:  2021-08-11

6.  Integration and Application of Multimodal Measurement Techniques: Relevance of Photogrammetry to Orthodontics.

Authors:  Dariusz Pojda; Agnieszka Anna Tomaka; Leszek Luchowski; Michał Tarnawski
Journal:  Sensors (Basel)       Date:  2021-12-01       Impact factor: 3.576

7.  Effect of Tooth Types on the Accuracy of Dental 3D Scanners: An In Vitro Study.

Authors:  Keunbada Son; Kyu-Bok Lee
Journal:  Materials (Basel)       Date:  2020-04-09       Impact factor: 3.623

8.  A Comparison of Full Arch Trueness and Precision of Nine Intra-Oral Digital Scanners and Four Lab Digital Scanners.

Authors:  Adam B Nulty
Journal:  Dent J (Basel)       Date:  2021-06-23
  8 in total