Literature DB >> 27926909

Dexamethasone Implant in Chronic Diabetic Macular Edema Resistant to Intravitreal Ranibizumab Treatment.

Ozlem Eski Yucel1, Ertugrul Can, Hilal Eser Ozturk, Hakki Birinci, Yuksel Sullu.   

Abstract

PURPOSE: The aim of this study was to assess the efficacy of a single intravitreal dexamethasone implant (IDI) over 6 months in eyes with chronic diabetic macular edema (DME) that were resistant to intravitreal ranibizumab (IR) treatment.
METHODS: This retrospective study was conducted at the Ondokuz Mayis University Hospital, Samsun, Turkey. Efficacy outcomes were considered as the change from baseline in best corrected visual acuity (BCVA) and central macular thickness (CMT).
RESULTS: Thirty eyes of 20 patients with a mean age of 61.6 ± 8.8 (45-85) years were included in the study. The mean BCVA significantly increased from 0.68 ± 0.27 to 0.56 ± 0.30 logMAR (p = 0.001) and 0.57 ± 0.30 logMAR (p = 0.002) at months 1 and 2, respectively. The proportion of patients who gained 3 or more lines in BCVA was 20%. The mean CMT significantly decreased from 578.93 ± 17.95 µm at baseline to 282.10 ± 21.42, 292.26 ± 19.69, 371.70 ± 21.23, and 463.60 ± 23.16 µm at months 1, 2, 3, and 4, respectively (p = 0.001). Intraocular pressure (IOP) increase occurred in 5 (16.7%) eyes. Cataract surgery was required in 3 (13%) out of 23 phakic eyes.
CONCLUSION: IDI provides significant benefits in visual acuity gains and anatomic improvements in eyes with chronic DME that are resistant to IR treatment. Increases in IOP and cataract progression can be observed in IDI-treated patients. However, its safety profile is acceptable.
© 2016 S. Karger AG, Basel.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27926909     DOI: 10.1159/000452422

Source DB:  PubMed          Journal:  Ophthalmic Res        ISSN: 0030-3747            Impact factor:   2.892


  3 in total

Review 1.  Efficacy and safety of single-dose dexamethasone implantation for patients with persistent diabetic macular edema: a systematic review and meta-analysis.

Authors:  Qiongzhen Yuan; Yilin Liu; Hanyue Xu; Yunxia Gao; Ling Qin; Yueqin Gou; Mengying Tao; Ming Zhang
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-09-22       Impact factor: 3.535

2.  The Efficacy of Single-Dose Intravitreal Dexamethasone Implant for Diabetic Macular Edema Refractory to Anti-VEGF Therapy: Real-Life Results.

Authors:  Mert Simsek; Mehmet Citirik; Serdar Ozates; Kemal Tekin; Dilara Ozkoyuncu
Journal:  Beyoglu Eye J       Date:  2020-02-19

Review 3.  Pharmacological Management of Diabetic Macular Edema in Real-Life Observational Studies.

Authors:  Laurent Kodjikian; David Bellocq; Thibaud Mathis
Journal:  Biomed Res Int       Date:  2018-08-28       Impact factor: 3.411

  3 in total