Literature DB >> 27923534

Rapid prototyped patient specific guiding implants in critical mandibular reconstruction.

Patricia Stoor1, Anni Suomalainen2, Karri Mesimäki1, Risto Kontio3.   

Abstract

Large tumours of the mandible need immediate reconstruction to provide continuity of the mandible, satisfactory function of the jaw, as well as an acceptable aesthetic outcome. In this prospective study we described the immediate reconstruction of the mandible using computer aided design and 15 rapid prototyped patient specific implants (PSI) in 14 patients suffering from benign or malignant tumours demanding continuity resection of the mandible. The scaffold PSI was filled with β-tricalcium phosphate granules and autologous bone. Microvascular reconstruction was additionally needed in 12/15 cases. The clinical follow up was on average 33 months and the radiological follow up was on average 21 months. In nine cases the healing was uneventful. One patient lost the microvascular flap during the first postoperative week and one patient needed a revision due to perforation of the mucosa at the site of the PSI. Four patients had a major complication due to perforation of the mucosa leading to infection, which resulted in the total or partial removal of the PSI. The PSI seems to be a promising solution for treatment of patients demanding large reconstruction after mandible resection. The benefits are decreased rate of donor site complications and more accurate and prompt surgical procedure.
Copyright © 2016. Published by Elsevier Ltd.

Entities:  

Keywords:  Mandibular reconstruction; Microvascular reconstruction; Rapid prototyped implants

Mesh:

Year:  2016        PMID: 27923534     DOI: 10.1016/j.jcms.2016.10.021

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  4 in total

1.  Design Criteria for Patient-specific Mandibular Continuity Defect Reconstructed Implant with Lightweight Structure using Weighted Topology Optimization and Validated with Biomechanical Fatigue Testing.

Authors:  Chun-Li Lin; Yu-Tzu Wang; Chun-Ming Chang; Cheng-Hsien Wu; Wei-Heng Tsai
Journal:  Int J Bioprint       Date:  2021-12-10

2.  Effect of Surface Tooling Techniques of Medical Titanium Implants on Bacterial Biofilm Formation In Vitro.

Authors:  Sonia Sarfraz; Pilvi-Helinä Mäntynen; Marisa Laurila; Juho Suojanen; Juha Saarnio; Sami Rossi; Jani Horelli; Mika Kaakinen; Junnu Leikola; Justus Reunanen
Journal:  Materials (Basel)       Date:  2022-04-29       Impact factor: 3.748

3.  Segmental Mandibular Reconstruction Using Tissue Engineering Strategies: A Systematic Review of Individual Patient Data.

Authors:  Vinay V Kumar; Elke Rometsch; Andreas Thor; Eppo Wolvius; Anahí Hurtado-Chong
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2020-04-08

4.  The Use of Customized Three-Dimensionally Printed Mandible Prostheses with a Pressure-Reducing Device: A Finite Element Analysis in Different Chewing Positions, Biomechanical Testing, and In Vivo Animal Study Using Lanyu Pigs.

Authors:  Chun-Feng Chen; Chun-Ming Chen; Han-Sheng Chen; Wei-Chin Huang; Yung-Chung Chen; Hung-Chih Chang; Sung-Ho Liu; Tsung-Lung Yang; Ling-Lin Wang; Ping-Ho Chen
Journal:  Biomed Res Int       Date:  2022-03-16       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.