Literature DB >> 27923250

Clinical Evaluation of the First Automated Assay for the Detection of Stimulating TSH Receptor Autoantibodies.

S Allelein1, M Ehlers1, S Goretzki1, D Hermsen2, J Feldkamp3, M Haase1, T Dringenberg1, C Schmid1, H Hautzel4, M Schott1.   

Abstract

Until recently, stimulating TSH receptor autoantibodies (sTRAbs) could only be measured by bioassays. A new assay system, which directly detects sTRAb in sera by applying bridge technology, has been established and is now available as automated chemiluminescence (bridge) immunoassay. We evaluated the automated bridge assay in clinical routine and compared it with a conventional automated TRAb assay (competition assay). Altogether, 226 Graves' disease (GD), 57 autoimmune thyroiditis, 74 non-autoimmune nodular goiter and 49 thyroid cancer patients, as well as 41 healthy controls were retrospectively evaluated. ROC plot analysis based on sera of newly diagnosed GD patients revealed an area under curve of 0.99 (95% CI: 0.99-1.0) indicating a high assay sensitivity and specificity. The highest sensitivity (100%) and specificity (99%) were seen at a cut-off level of 0.55 IU/l. The calculated positive predictive value was 94%, whereas the negative was 100%. Applying a ROC plot-derived cut-off of≥0.30 IU/l, derived from sera of GD patients already receiving antithyroid drug therapy for≤6 months, the sensitivity was 99% whereas the specificity was 98%. Detailed comparison of both assay systems used revealed a slightly different distribution of sTRAb and TRAb. Measurement of sTRAb during follow-up revealed a steady decline over one year of follow-up. In summary, our results demonstrate that the new automated bridge assay system for detecting sTRAb has a high sensitivity and specificity for diagnosing GD and to discriminate from other thyroid diseases, respectively. Our study, however, does not provide full evidence that the bridge assay is specific for sTRAb only. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27923250     DOI: 10.1055/s-0042-121012

Source DB:  PubMed          Journal:  Horm Metab Res        ISSN: 0018-5043            Impact factor:   2.936


  3 in total

1.  A novel third-generation TSH receptor antibody (TRAb) enzyme-linked immunosorbent assay based on a murine monoclonal TSH receptor-binding antibody.

Authors:  Johannes J Roggenbuck; Miklos Veiczi; Karsten Conrad; Peter Schierack; Gerd Wunderlich; Joerg Kotzerke; Dirk Roggenbuck; Klaus Zöphel
Journal:  Immunol Res       Date:  2018-12       Impact factor: 2.829

2.  Diagnostic accuracy of a new fluoroenzyme immunoassay for the detection of TSH receptor autoantibodies in Graves' disease.

Authors:  Danilo Villalta; Federica D'Aurizio; Mirella Da Re; Debora Ricci; Francesco Latrofa; Renato Tozzoli
Journal:  Auto Immun Highlights       Date:  2018-02-12

3.  Clinical evaluation of an automated TSI bridge immunoassay in the diagnosis of Graves' disease and its relationship to the degree of hyperthyroidism.

Authors:  Tianqi Liu; Xiuying Zhang; Li Long; Lingli Zhou; Jing Chen; Meng Li; Ying Gao; Xianghai Zhou; Xueyao Han; Linong Ji
Journal:  BMC Endocr Disord       Date:  2022-08-31       Impact factor: 3.263

  3 in total