Literature DB >> 27921064

Over-the-Scope Clip Closure of a Colon Perforation Caused by an Ingested Wooden Toothpick.

Sebastian Luense1, Peter Simon2, Claus-Dieter Heidecke1, Anne Glitsch1.   

Abstract

Entities:  

Year:  2016        PMID: 27921064      PMCID: PMC5126503          DOI: 10.14309/crj.2016.138

Source DB:  PubMed          Journal:  ACG Case Rep J        ISSN: 2326-3253


× No keyword cloud information.

Case Report

A 62-year-old male presented with abdominal pain in the right lower quadrant for 1 day. The patient’s history included an ambulant colonoscopy with no pathological findings 3 weeks prior. Clinical examination revealed tenderness in the right hypochondrium. Moderate inflammation with C-reactive protein 56.6 mg/L but normal white blood cell count was assessed. An enhanced computed tomography scan of the abdomen showed signs of non-specific segmental colitis in the ascending colon (Figure 1). Colonoscopy revealed a perforation of the ascending colon by a double-pointed wooden toothpick (Figure 2).
Figure 1

Enhanced computed tomography revealed segmental wall thickening in ascending colon (arrow).

Figure 2

Colonoscopy showed a wooden toothpick impacted in the ascending colon.

Enhanced computed tomography revealed segmental wall thickening in ascending colon (arrow). Colonoscopy showed a wooden toothpick impacted in the ascending colon. The foreign body was successfully removed endoscopically using a disposable polypectomy snare. After complete removal of the toothpick, the endoscope was withdrawn, re-inserted with a mounted and loaded over-the-scope clip (OTSC) device, and positioned toward the perforation site (Figure 3). After the tissue was grasped with an OTSC anchor, a 9-mm OTSC was released and the perforation site was closed (Figure 4). The postinterventional period was uneventful. Follow-up colonoscopy 2 weeks later revealed no displacement of the OTSC or other complications.
Figure 3

Perforation site after complete removal of the toothpick.

Figure 4

Endoscopic image of successful closure of the perforation site by an over-the-scope clip.

Perforation site after complete removal of the toothpick. Endoscopic image of successful closure of the perforation site by an over-the-scope clip. Ingestion of a toothpick is a rare incident, and gastrointestinal (GI) perforation has been reported to occur in 0.2 per 100,000 people every year in the United States.1 Extremes of age, personality disorders, mental retardation, artificial dentures, palatal insensitivity, and alcoholism have been described as predisposing factors.2 Diagnosis is difficult due to unspecific clinical findings, and toothpicks were apparent with imaging techniques in only 14% of cases.3 Most patients present with abdominal pain (70%), as our patient did.3 Definitive diagnosis of a toothpick injury is commonly made at laparotomy (53%) followed by endoscopy (19%).3 The most common sites of perforation are the duodenum and sigmoid colon.3 Complications include bleeding, obstruction, fistula formation, sepsis, and death, with an overall mortality of 18%.3,4 In the past, standard treatment for GI toothpick perforation had been surgery. Recently, invasive endoscopic treatment has provided an alternative approach. One of the recently established devices is the OTSC system, which has been developed for hemostasis of GI bleeding as well as closure of iatrogenic perforations of the colon. GI defects <30 mm in diameter can be closed with OTSC.5 Our case report demonstrates the successful endoscopic treatment of a colon perforation caused by a toothpick using the OTSC system, without the need for surgery.

Disclosures

Author contributions: S. Luense wrote the manuscript, reviewed the literature, and is the article guarantor. P. Simon, CD Heidecke, and A. Glitsch edited and reviewed the manuscript. Financial disclosure: None to report. Informed consent was obtained for this case report.
  5 in total

1.  Endoscopic full-thickness resection and defect closure in the colon.

Authors:  Daniel von Renteln; Arthur Schmidt; Melina C Vassiliou; Hans-Ulrich Rudolph; Karel Caca
Journal:  Gastrointest Endosc       Date:  2010-06       Impact factor: 9.427

2.  Ingested toothpick fistula of the ileum mimicking Crohn's disease.

Authors:  O Ioannidis; E Kakoutis; L Sakkas; A Konstantara; S Chatzopoulos; A Kotronis; N Makrantonakis
Journal:  Acta Gastroenterol Belg       Date:  2010 Oct-Dec       Impact factor: 1.316

3.  An unusual presentation of toothpick penetration of colon.

Authors:  Imtiaz Wani; Shamima A Wani; Shabir Mir; Khursheed Parra
Journal:  J Emerg Trauma Shock       Date:  2010-10

4.  Toothpick-related injuries in the United States, 1979 through 1982.

Authors:  L D Budnick
Journal:  JAMA       Date:  1984-08-10       Impact factor: 56.272

Review 5.  Toothpick injury mimicking renal colic: case report and systematic review.

Authors:  Siu Fai Li; Kimberly Ender
Journal:  J Emerg Med       Date:  2002-07       Impact factor: 1.484

  5 in total
  2 in total

1.  Successful Endoscopic Removal of Toothpick Perforating Gastric Antrum With Over-the-Scope Padlock Clip Closure.

Authors:  Darshan Suthar; Elisabeth H Kramer; Harshit S Khara
Journal:  Cureus       Date:  2020-10-30

2.  Endoscopic removal of an impacted wooden toothpick in the wall of the sigmoid colon.

Authors:  Artur Zakościelny; Witold Zgodziński; Grzegorz Wallner; Krzysztof Zinkiewicz
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2018-05-21       Impact factor: 1.195

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.