Literature DB >> 27920895

Organosilane-functionalization of nanostructured indium tin oxide films.

R Pruna1, F Palacio1, M Martínez2, O Blázquez1, S Hernández1, B Garrido1, M López1.   

Abstract

Fabrication and organosilane-functionalization and characterization of nanostructured ITO electrodes are reported. Nanostructured ITO electrodes were obtained by electron beam evaporation, and a subsequent annealing treatment was selectively performed to modify their crystalline state. An increase in geometrical surface area in comparison with thin-film electrodes area was observed by atomic force microscopy, implying higher electroactive surface area for nanostructured ITO electrodes and thus higher detection levels. To investigate the increase in detectability, chemical organosilane-functionalization of nanostructured ITO electrodes was performed. The formation of 3-glycidoxypropyltrimethoxysilane (GOPTS) layers was detected by X-ray photoelectron spectroscopy. As an indirect method to confirm the presence of organosilane molecules on the ITO substrates, cyclic voltammetry and electrochemical impedance spectroscopy (EIS) were also carried out. Cyclic voltammograms of functionalized ITO electrodes presented lower reduction-oxidation peak currents compared with non-functionalized ITO electrodes. These results demonstrate the presence of the epoxysilane coating on the ITO surface. EIS showed that organosilane-functionalized electrodes present higher polarization resistance, acting as an electronic barrier for the electron transfer between the conductive solution and the ITO electrode. The results of these electrochemical measurements, together with the significant difference in the X-ray spectra between bare ITO and organosilane-functionalized ITO substrates, may point to a new exploitable oxide-based nanostructured material for biosensing applications. As a first step towards sensing, rapid functionalization of such substrates and their application to electrochemical analysis is tested in this work. Interestingly, oxide-based materials are highly integrable with the silicon chip technology, which would permit the easy adaptation of such sensors into lab-on-a-chip configurations, providing benefits such as reduced size and weight to facilitate on-chip integration, and leading to low-cost mass production of microanalysis systems.

Entities:  

Keywords:  X-ray photoelectron spectroscopy; atomic force microscopy; cyclic voltammetry; electrochemical impedance spectroscopy; electrochemistry; indium tin oxide

Year:  2016        PMID: 27920895      PMCID: PMC5071817          DOI: 10.1098/rsfs.2016.0056

Source DB:  PubMed          Journal:  Interface Focus        ISSN: 2042-8898            Impact factor:   3.906


  11 in total

Review 1.  Application of conducting polymers to biosensors.

Authors:  Manju Gerard; Asha Chaubey; B D Malhotra
Journal:  Biosens Bioelectron       Date:  2002-05       Impact factor: 10.618

Review 2.  Conducting polymers in electronic chemical sensors.

Authors:  Jiri Janata; Mira Josowicz
Journal:  Nat Mater       Date:  2003-01       Impact factor: 43.841

3.  Nanomaterial-based electrochemical biosensors.

Authors:  Joseph Wang
Journal:  Analyst       Date:  2005-04       Impact factor: 4.616

Review 4.  Nanostructures in biodiagnostics.

Authors:  Nathaniel L Rosi; Chad A Mirkin
Journal:  Chem Rev       Date:  2005-04       Impact factor: 60.622

5.  Advanced surface modification of indium tin oxide for improved charge injection in organic devices.

Authors:  Eric L Hanson; Jing Guo; Norbert Koch; Jeffrey Schwartz; Steven L Bernasek
Journal:  J Am Chem Soc       Date:  2005-07-20       Impact factor: 15.419

6.  Silane layers on silicon surfaces: mechanism of interaction, stability, and influence on protein adsorption.

Authors:  Nesrine Aissaoui; Latifa Bergaoui; Jessem Landoulsi; Jean-François Lambert; Souhir Boujday
Journal:  Langmuir       Date:  2011-12-23       Impact factor: 3.882

7.  Development of electrochemical based sandwich enzyme linked immunosensor for Cryptosporidium parvum detection in drinking water.

Authors:  Chinnasamy Thiruppathiraja; Veerappan Saroja; Senthilkumar Kamatchiammal; Periyakaruppan Adaikkappan; Muthukaruppan Alagar
Journal:  J Environ Monit       Date:  2011-09-07

8.  Sensitive electrochemiluminescence biosensor based on Au-ITO hybrid bipolar electrode amplification system for cell surface protein detection.

Authors:  Mei-Sheng Wu; Da-Jing Yuan; Jing-Juan Xu; Hong-Yuan Chen
Journal:  Anal Chem       Date:  2013-11-21       Impact factor: 6.986

9.  Immunobiosensor chips for detection of Escherichia coil O157:H7 using electrochemical impedance spectroscopy.

Authors:  Chuanmin Ruan; Liju Yang; Yanbin Li
Journal:  Anal Chem       Date:  2002-09-15       Impact factor: 6.986

10.  Optoelectric biosensor using indium-tin-oxide electrodes.

Authors:  Chang Kyoung Choi; Kenneth D Kihm; Anthony E English
Journal:  Opt Lett       Date:  2007-06-01       Impact factor: 3.776

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.