Literature DB >> 27920333

Accuracy and Reproducibility Using Patient-Specific Instrumentation in Total Ankle Arthroplasty.

Justin Daigre1, Gregory Berlet2, Bryan Van Dyke3, Kyle S Peterson4, Robert Santrock5.   

Abstract

BACKGROUND: Implant survivorship is dependent on accuracy of implantation and successful soft tissue balancing. System instrumentation for total ankle arthroplasty implantation has a key influence on surgeon accuracy and reproducibility. The purpose of this study was to determine the accuracy and reproducibility of implant position with patient-specific guides for total ankle arthroplasty across multiple surgeons at multiple facilities.
METHODS: This retrospective, multicenter study included 44 patients who received a total ankle implant (INBONE II Total Ankle System; Wright Medical Technology, Memphis, TN) using PROPHECY patient-specific guides from January 2012 to December 2014. Forty-four patients with an average age of 63.0 years underwent total ankle arthroplasty using this preoperative patient-specific system. Preoperative computed tomography (CT) scans were obtained to assess coronal plane deformity, assess mechanical and anatomic alignment, and build patient-specific guides that referenced bony anatomy. The mean preoperative coronal deformity was 4.6 ± 4.6 degrees (range, 14 degrees varus to 17 degrees valgus). The first postoperative weightbearing radiographs were used to measure coronal and sagittal alignment of the implant vs the anatomic axis of the tibia.
RESULTS: In 79.5% of patients, the postoperative implant position of the tibia corresponded to the preoperative plan of the tibia within 3 degrees of the intended target, within 4 degrees in 88.6% of patients, and within 5 degrees in 100% of patients. The tibial component coronal size was correctly predicted in 98% of cases, whereas the talar component was correctly predicted in 80% of cases.
CONCLUSION: The use of patient-specific instrumentation for total ankle arthroplasty provided reliable alignment and reproducibility in the clinical situation similar to that shown in cadaveric testing. This study has shown that the preoperative patient-specific instrumentation provided for accuracy and reproducibility of ankle arthroplasty implantation in a cohort across multiple surgeons and facilities. LEVEL OF EVIDENCE: Level III, retrospective comparative series.

Entities:  

Keywords:  ankle arthroplasty; arthritis; implant; joint replacement; patient-specific instrumentation

Mesh:

Year:  2016        PMID: 27920333     DOI: 10.1177/1071100716682086

Source DB:  PubMed          Journal:  Foot Ankle Int        ISSN: 1071-1007            Impact factor:   2.827


  8 in total

Review 1.  Preoperative Guidance With Weight-Bearing Computed Tomography and Patient-Specific Instrumentation in Foot and Ankle Surgery.

Authors:  Jacob Zeitlin; Jensen Henry; Scott Ellis
Journal:  HSS J       Date:  2021-07-07

2.  Patient-specific instrumentation (PSI) in total ankle arthroplasty: a systematic review.

Authors:  Qiuyuan Wang; Nianfei Zhang; Wanshou Guo; Weiguo Wang; Qidong Zhang
Journal:  Int Orthop       Date:  2021-08-04       Impact factor: 3.075

3.  Infinity ankle arthroplasty with traditional instrumentation and PSI prophecy system: preliminary results.

Authors:  Piero Giardini; Paolo Di Benedetto; Domenico Mercurio; Renato Gisonni; Marco Molinari; Araldo Causero; Fabrizio Cortese
Journal:  Acta Biomed       Date:  2020-12-30

4.  Accuracy of Weightbearing CT Scans for Patient-Specific Instrumentation in Total Ankle Arthroplasty.

Authors:  Mitchell J Thompson; Devon Consul; Benjamin D Umbel; Gregory C Berlet
Journal:  Foot Ankle Orthop       Date:  2021-12-08

Review 5.  Patient-specific instrumentation in total ankle arthroplasty.

Authors:  Antonio Mazzotti; Alberto Arceri; Simone Zielli; Simone Bonelli; Valentina Viglione; Cesare Faldini
Journal:  World J Orthop       Date:  2022-03-18

6.  Patient-Specific Instrumentation vs Standard Referencing in Total Ankle Arthroplasty: A Comparison of the Radiologic Outcome.

Authors:  Lukas Heisler; Werner Vach; Georg Katz; Thomas Egelhof; Markus Knupp
Journal:  Foot Ankle Int       Date:  2022-02-24       Impact factor: 3.569

7.  A new ligament-compatible patient-specific 3D-printed implant and instrumentation for total ankle arthroplasty: from biomechanical studies to clinical cases.

Authors:  C Faldini; A Mazzotti; C Belvedere; G Durastanti; A Panciera; G Geraci; A Leardini
Journal:  J Orthop Traumatol       Date:  2020-09-02

8.  The Infinity Total Ankle System: Early Clinical Results With 2- to 4-Year Follow-up.

Authors:  Murray Penner; W Hodges Davis; Kevin Wing; Thomas Bemenderfer; Feras Waly; Robert B Anderson
Journal:  Foot Ankle Spec       Date:  2018-06-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.