Literature DB >> 27918347

The Stereo-Electroencephalography: The Epileptogenic Zone.

Jorge A Gonzalez-Martinez1.   

Abstract

The stereo-electroencephalography (SEEG) methodology and technique was developed almost 60 years ago in Europe and it has proven its efficacy and safety over the last 55 years. The main advantage of the SEEG method is the possibility to study the epileptogenic neuronal network in its dynamic and tri-dimensional aspect, with an optimal time and space correlation with the clinical semiology. In this manuscript, the technical and methodological aspects of the SEEG will be discussed focusing on the planning of SEEG implantations, technical nuances, conceptualization of the epileptogenic zone, and the different methods of SEEG-guided surgical resections and ablations.

Mesh:

Year:  2016        PMID: 27918347     DOI: 10.1097/WNP.0000000000000327

Source DB:  PubMed          Journal:  J Clin Neurophysiol        ISSN: 0736-0258            Impact factor:   2.177


  9 in total

Review 1.  Stereoelectroencephalography Versus Subdural Electrodes for Localization of the Epileptogenic Zone: What Is the Evidence?

Authors:  Joel S Katz; Taylor J Abel
Journal:  Neurotherapeutics       Date:  2019-01       Impact factor: 7.620

2.  Resting-State SEEG May Help Localize Epileptogenic Brain Regions.

Authors:  Sarah E Goodale; Hernán F J González; Graham W Johnson; Kanupriya Gupta; William J Rodriguez; Robert Shults; Baxter P Rogers; John D Rolston; Benoit M Dawant; Victoria L Morgan; Dario J Englot
Journal:  Neurosurgery       Date:  2020-06-01       Impact factor: 4.654

Review 3.  Stereo-Encephalographic Presurgical Evaluation of Temporal Lobe Epilepsy: An Evolving Science.

Authors:  Elma Paredes-Aragon; Norah A AlKhaldi; Daniel Ballesteros-Herrera; Seyed M Mirsattari
Journal:  Front Neurol       Date:  2022-05-27       Impact factor: 4.086

Review 4.  A modern epilepsy surgery treatment algorithm: Incorporating traditional and emerging technologies.

Authors:  Dario J Englot
Journal:  Epilepsy Behav       Date:  2018-02-02       Impact factor: 2.937

5.  Memory decline from hippocampal electrodes? Let's not forget statistics and study design.

Authors:  Dario J Englot; John D Rolston
Journal:  Epilepsia       Date:  2018-02       Impact factor: 5.864

Review 6.  Diagnosis and Surgical Treatment of Drug-Resistant Epilepsy.

Authors:  Chinekwu Anyanwu; Gholam K Motamedi
Journal:  Brain Sci       Date:  2018-03-21

7.  Identifying the Epileptogenic Zone With the Relative Strength of High-Frequency Oscillation: A Stereoelectroencephalography Study.

Authors:  Lei Qi; Xing Fan; Xiaorong Tao; Qi Chai; Kai Zhang; Fangang Meng; Wenhan Hu; Lin Sang; Xiaoli Yang; Hui Qiao
Journal:  Front Hum Neurosci       Date:  2020-06-09       Impact factor: 3.169

8.  Gray Matter Sampling Differences Between Subdural Electrodes and Stereoelectroencephalography Electrodes.

Authors:  Mohamed Tantawi; Jingya Miao; Caio Matias; Christopher T Skidmore; Michael R Sperling; Ashwini D Sharan; Chengyuan Wu
Journal:  Front Neurol       Date:  2021-04-27       Impact factor: 4.003

9.  SEEG in 3D: Interictal Source Localization From Intracerebral Recordings.

Authors:  David Satzer; Yasar T Esengul; Peter C Warnke; Naoum P Issa; Douglas R Nordli
Journal:  Front Neurol       Date:  2022-02-08       Impact factor: 4.003

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.