Robert Zivadinov1,2, Nasreen Khan3, Jennie Medin4, Pia Christoffersen3, Jennifer Price3, Jonathan R Korn5, Ian Bonzani6, Michael G Dwyer1, Niels Bergsland1,7, Ellen Carl1, Diego Silva4, Bianca Weinstock-Guttman8.
Abstract
BACKGROUND &Entities:
Keywords: MRI; Multiple sclerosis; brain volume; fingolimod (Gilenya®); lesion
Mesh:
Substances:
Year: 2016 PMID: 27918139 PMCID: PMC5434824 DOI: 10.1111/jon.12411
Source DB: PubMed Journal: J Neuroimaging ISSN: 1051-2284 Impact factor: 2.486
Figure 1Diagrammatic representation of study approach. Gd = gadolinium; MS = multiple sclerosis; MRI = magnetic resonance imaging; eCRF = electronic Case Report Form; RRMS = relapsing‐remitting multiple sclerosis.
Figure 2Study design.
Clinical Information and MRI Data Collected
| Data Variables and Time Points of Collection | −24 Months | −18 Months | −12 Months | −6 Months | Index Date | 6 Months | 12 Months | 18 Months | 24 Months |
|---|---|---|---|---|---|---|---|---|---|
| Clinical information via eCRF | |||||||||
| I/E criteria | X | ||||||||
| Demographics | X | ||||||||
| MS history | X | ||||||||
| BMI | X | X | X | X | X | X | X | X | X |
| MS medication | X | X | X | X | X | X | X | X | X |
| Other medication | X | X | X | X | X | X | X | X | X |
| MS symptoms | X | X | X | X | X | X | X | X | X |
| Relapses | X | X | X | X | X | X | X | X | X |
| FSS/EDSS | X | X | |||||||
| T25‐FW | X | X | X | X | X | X | X | X | X |
| Comorbidities | X | X | X | X | X | X | X | X | X |
| Hospitalizations | X | X | X | X | X | X | X | X | X |
| ER visits | X | X | X | X | X | X | X | X | X |
| MRI measures via brain MRI scans | |||||||||
| Global atrophy measures | X | X | X | ||||||
| Lesion measures | X | X | X | ||||||
aNote that the time does not represent explicit time points rather any visit that happened between the current visit and last reported visit. In routine practice, they are generally 6 months apart.
bRequired to record or estimate an EDSS score for the visits closest to the index and postindex MRI scan dates; other EDSS scores may be captured as well.
cMRI data are collected at the following intervals: Preindex scan: 9–24 months before index date (optional); index scan: 6 months before to 1 month after index date; postindex scan: 9–24 months after index date.
eCRF = electronic Case Report Form; BMI = body mass index; MS = multiple sclerosis; EDSS = Expanded Disability Status Scale; ER = emergency room; I/E = inclusion/exclusion; FSS = Functional Systems Scores; MRI = magnetic resonance imaging; T25‐FW = Timed 25‐Feet Walk.
Figure 3Anonymization pathway. Pathway 1: Scans are parsed through a local secure Java applet running within the local site computer's browser, where they are stripped of all protected health information by an anonymizer compliant with Digital Imaging and Communications in Medicine (DICOM) PS3.15 2015b Annex E. Only after anonymization, does any data leave the local site through an encrypted Internet tunnel. PACS = picture archiving communication system; CD = CD‐ROM; HTTPS = Hyper Text Transfer Protocol Secure; TLS = transport layer security; PI = principal investigator; CRO = clinical research organization.
Figure 4Geographical distribution of centers. The numbers illustrate the total numbers of centers interested in the study as of end of February 2016 and the numbers in brackets the number of enrolled sites.
Characteristics of the Included Patients
| Characteristics |
| |
|---|---|---|
| Patients with index and postindex scan | 250 | 99.2% |
| Patients with preindex, index, and postindex scan | 86 | 34.1% |
| Age at index date (years): mean (SD) | 43.3 | (9.3) |
| Gender: ( | ||
| Male | 49 | 19.4% |
| Female | 203 | 80.6% |
| Race/Ethnicity: ( | ||
| Caucasian/White | 211 | 83.7% |
| Non‐Caucasian | 23 | 9.1% |
| Unknown | 18 | 7.1% |
| Health insurance: ( | ||
| Private | 193 | 77.6% |
| Public | 43 | 17.1% |
| Mixed | 4 | 1.6% |
| Other | 1 | .4% |
| Unknown | 11 | 4.4% |
| Marital Status: ( | ||
| No partner (single/divorced/separated/widowed) | 58 | 23.0% |
| Partner (married/cohabitating/partnered) | 175 | 69.4% |
| Unknown | 19 | 7.5% |
| Preindex days (first visit to index MRI): mean (SD) | 379.0 | (239.2) |
| Postindex days (index MRI to postindex MRI): mean (SD) | 505.9 | (145.5) |
| Duration with MS (years): mean (SD) | 9.6 | (6.8) |
| Number of relapses in 2 years before index: mean (SD) | .58 | (.85) |
aTwo patients were excluded as there was scan quality indicator data that were not available for these patients at the time of analysis.
SD = standard deviation; n = number; % = percentage; MRI = magnetic resonance imaging.
Description of Scan Collection and Quality Control Assessment
| Characteristics | Preindex ( | Index ( | Postindex ( |
|---|---|---|---|
| Scanner strength | |||
| 1.5 T | 73.3 | 63.5 | 59.6 |
| 3 T | 26.7 | 36.5 | 40.4 |
| Pulse sequence: | |||
| 2D T1‐WI | 84.9 | 70.2 | 64.4 |
| 3D T1‐WI | 39.5 | 43.3 | 50.0 |
| 2D or 3D FLAIR | 100.0 | 100.0 | 99.6 |
| 2D T1‐WI and 3D T1‐WI | 26.7 | 16.7 | 17.2 |
| 2D or 3D FLAIR quality: | |||
| Slice thickness: | |||
| < = 5 mm | 50.7 | 40.9 | 39.5 |
| >5 mm | 49.3 | 59.1 | 60.5 |
| Excessive patient motion: | |||
| Yes | .0 | 1.1 | 1.1 |
| No | 100.0 | 98.9 | 98.9 |
| Scanner contrast: | |||
| Bad | 1.4 | 3.3 | .5 |
| Acceptable | 27.4 | 16.0 | 19.5 |
| Good | 71.2 | 80.7 | 80.0 |
| Overall scan quality: | |||
| Bad | 4.1 | 5.0 | 1.1 |
| Acceptable | 46.6 | 54.1 | 53.0 |
| Good | 49.3 | 40.9 | 45.9 |
| 3D T1‐WI quality: | |||
| Slice thickness: | |||
| < = 2 mm | 85.3 | 83.2 | 85.6 |
| >2 mm | 14.7 | 16.8 | 14.4 |
| Excessive patient motion: | |||
| Yes | .0 | .0 | .0 |
| No | 100.0 | 100.0 | 100.0 |
| Scanner contrast: | |||
| Bad | .0 | .0 | .8 |
| Acceptable | 5.9 | 4.4 | 1.5 |
| Good | 94.1 | 95.6 | 97.7 |
| Overall scan quality: | |||
| Bad | .0 | .9 | .8 |
| Acceptable | 17.6 | 21.2 | 14.4 |
| Good | 82.4 | 77.9 | 84.8 |
| 2D FLAIR quality: | |||
| Slice thickness: | |||
| < = 5 mm | 58.1 | 61.9 | 66.0 |
| >5 mm | 41.9 | 38.1 | 34.0 |
| Excessive patient motion: | |||
| Yes | 5.8 | .8 | 2.4 |
| No | 94.2 | 99.2 | 97.6 |
| Scanner contrast: | |||
| Bad | .0 | .4 | 1.2 |
| Acceptable | 22.1 | 19.0 | 25.6 |
| Good | 77.9 | 80.6 | 73.2 |
| Overall scan quality: | |||
| Bad | 3.5 | 4.0 | 7.2 |
| Acceptable | 25.6 | 21.4 | 25.6 |
| Good | 70.9 | 74.6 | 67.2 |
T = Tesla; WI = weighted image; FLAIR = fluid‐attenuated inversion recovery; mm = millimeter.
Description of MRI Scan Hardware, Software, and Protocol Changes over the Follow‐Up
| Characteristics | Preindex to Index ( | Index to Postindex ( |
|---|---|---|
| Machine difference: (%) | ||
| Yes | 31.4% | 26.0% |
| No | 68.6% | 74.0% |
| Software difference: (%) | ||
| Yes | 17.4% | 26.4% |
| No | 82.6% | 73.6% |
| Coil difference: (%) | ||
| Yes | 20.9% | 36.0% |
| No | 50.0% | 39.6% |
| Unknown | 29.1% | 24.4% |
| Hardware or software difference: ( | ||
| Yes | 39.5% | 50.0% |
| No | 41.9% | 35.2% |
| Unknown | 18.6% | 14.8% |
| 2D or 3D FLAIR | ||
| Orientation, thickness, or protocol different: (%) | ||
| Yes | 55.8% | 35.5% |
| No | 44.2% | 64.5% |
| Hardware, software, or protocol difference: (%) | ||
| Yes | 57.0% | 55.4% |
| No | 32.6% | 32.1% |
| Unknown | 10.5% | 12.4% |
| 2D T1‐WI | ||
| Orientation, thickness, or protocol difference: (%) | ||
| Yes | 31.9% | 29.1% |
| No | 68.1% | 70.9% |
| Hardware, software, or protocol difference: (%) | ||
| Yes | 44.9% | 55.7% |
| No | 36.2% | 31.6% |
| Unknown | 18.8% | 12.7% |
| 3D T1‐WI | ||
| Orientation, thickness, or protocol difference: (%) | ||
| Yes | 26.7% | 20.4% |
| No | 73.3% | 79.6% |
| Hardware, software, or protocol difference: (%) | ||
| Yes | 30.0% | 44.7% |
| No | 66.7% | 44.7% |
| Unknown | 3.3% | 10.7% |
FLAIR = fluid‐attenuated inversion recovery; WI = weighted image.