Literature DB >> 27915262

Procedural outcomes of fluoroless catheter ablation outside the traditional catheterization lab.

Amee M Bigelow1, Philip C Smith1, Dylan T Timberlake1, Neil L McNinch2, Grace L Smith1, John R Lane1, John M Clark1.   

Abstract

AIMS: Non-fluoroscopic catheter ablation is becoming routine. In experienced centres, fluoroscopy is rarely required. The use of a traditional catheterization lab (cath lab) may no longer be necessary. We began performing catheter ablations at a paediatric centre outside the traditional cardiac cath lab in 2013. The purpose of this study was to compare procedural features of paediatric catheter ablation performed outside the cath lab to those performed within a cath lab. METHODS AND
RESULTS: We prospectively looked at patients presenting to the paediatric centre with supraventricular tachycardia (SVT) undergoing catheter ablation outside the cath lab in a standard operating room (OR group). We compared retrospectively to a control group matched for age, type, and location of arrhythmia who had ablations in a traditional cath lab (CL group). Catheter visualization was exclusively by electro-anatomic mapping. Fifty-nine patients with SVT underwent catheter ablation in the OR from October 2013 to December 2015. Thirty-three patients had accessory pathways, 29 were manifest, and 13 of those were left sided. Twenty-six had atrioventricular nodal re-entrant tachycardia. Transseptal puncture with transoesophageal echocardiography guidance was used for 10 left-sided pathways, whereas the other 3 had patent foramen ovales. Procedure time did not differ significantly between groups (OR group mean 131 min, range 57-408; CL group mean 152 min, range 68-376; P = 0.12). Acute success was similar in both groups [OR group: 58/59 (98.3%) and CL group: 57/59 (96.6%)]. There were no major complications in either group. There was no fluoroscopy used in either group.
CONCLUSION: Although performing paediatric catheter ablations outside the traditional cath lab is early in our experience, we produced similar outcomes and results without encountering procedural difficulties of performing ablations in a non-conventional setting. Larger multi-centred trials will be essential to determine the feasibility of this practice. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2016. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  Ablation; No fluoroscopy; Paediatric; Supraventricular tachycardia

Mesh:

Year:  2017        PMID: 27915262     DOI: 10.1093/europace/euw207

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  2 in total

1.  Safety steps for a non-fluoroscopic approach in right-sided electrophysiology procedures: A point of view.

Authors:  Franco Zoppo; Claudia Licciardello; Giulia Favaro; Alessandra Scalon; Enrico Bacchiega; Antonio Lupo; Giacomo Mugnai; Francesca Zerbo
Journal:  Indian Pacing Electrophysiol J       Date:  2019-03-23

Review 2.  ALARA in Pediatric Electrophysiology Laboratory.

Authors:  Harinder R Singh
Journal:  Children (Basel)       Date:  2022-06-10
  2 in total