| Literature DB >> 27914737 |
Soumita Ghosh1, Isabel González-Mariscal1, Josephine M Egan1, Ruin Moaddel2.
Abstract
Cannabinoid receptors (CBR), including CB1 and CB2 have been therapeutic targets for a number of conditions. Recently, splice variants of the CB1R have been identified in humans. The isoforms differ in their N-terminus sequence and pharmacological activity relative to the CB1R, as a result, the differentiation between the CB1 receptor and its isoform is required. As a result, a selected reaction monitoring mass spectrometry (SRM-MS) method was developed for the quantitation of CB1 and the CB1b isoform in CHO cells transduced with CB1 and CB1b. The SRM-MS protocol was assessed with isotopically labeled peptide standards and had high reproducibility of intra-day assay (CVs from 1.9 to 4.3% for CB1 and 0.5 to 5.9% for CB1b) and inter-day assay (CVs from 1.2 to 5.2% for CB1 and 1.2 to 6.1% for CB1b). Published by Elsevier B.V.Entities:
Keywords: CB1; CB1b; Cannabinoid receptor isoforms; SRM assay
Mesh:
Substances:
Year: 2016 PMID: 27914737 PMCID: PMC5426998 DOI: 10.1016/j.jpba.2016.11.003
Source DB: PubMed Journal: J Pharm Biomed Anal ISSN: 0731-7085 Impact factor: 3.935