Literature DB >> 27914608

Evaluation of size exclusion chromatography columns packed with sub-3μm particles for the analysis of biopharmaceutical proteins.

Alexandre Goyon1, Alain Beck2, Olivier Colas2, Koen Sandra3, Davy Guillarme1, Szabolcs Fekete4.   

Abstract

The aim of this study was to evaluate the practical possibilities and limitations of several recently introduced size exclusion chromatographic (SEC) columns of 150×4.6mm, sub-3μm (Agilent AdvanceBioSEC 2.7μm, Tosoh TSKgel UP-SW3000 2.0μm, Phenomenex Yarra SEC X-150 1.8μm and Waters Acquity BEH200 1.7μm) for the separation of biopharmaceutical proteins. For this purpose, some model proteins were tested, as well as several commercial therapeutic monoclonal antibodies (mAbs) and antibody-drug-conjugates (ADCs). Calibration curves were drawn to highlight the applicability of these new SEC columns for the separation of mAbs, ADCs and their aggregates, despite some differences in their nominal pore diameter (vary from 150 to 300Å). The kinetic performance (van Deemter curves and kinetic pots) was evaluated. Columns packed with 1.7-2.0μm particles improved the plate count by a factor of 1.5-2 compared to 2.7μm particles, which is in agreement with theoretical expectations. Finally, possible secondary hydrophobic and/or electrostatic interactions between the SEC stationary phases and biopharmaceutical proteins were systematically studied. Significant differences in nonspecific interactions were observed, with hydrophobic interactions generally exerting more influence than electrostatic interactions. The use of a novel bond chemistry with the AdvanceBioSEC column was found highly effective to limit non-specific interactions and pave the way to further improvements for column provider. At the end, the average resolutions achieved on the four sub-3μm SEC columns between monomer and dimer structures were comparable for ten approved mAbs products.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aggregates; Antibody-drug-conjugates; Kinetic efficiency; M SEC columns; Monoclonal antibodies; Size exclusion chromatography

Mesh:

Substances:

Year:  2016        PMID: 27914608     DOI: 10.1016/j.chroma.2016.11.056

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

Review 1.  Next-generation Interactomics: Considerations for the Use of Co-elution to Measure Protein Interaction Networks.

Authors:  Daniela Salas; R Greg Stacey; Mopelola Akinlaja; Leonard J Foster
Journal:  Mol Cell Proteomics       Date:  2019-12-02       Impact factor: 5.911

2.  Analytical combinations to evaluate the macromolecular composition of extracellular substances (ECS) from Lactobacillus plantarum cell culture media.

Authors:  Peio Elichiry-Ortiz; Pauline Maes; Stéphanie Weidmann; Dominique Champion; Christian Coelho
Journal:  Anal Bioanal Chem       Date:  2020-11-05       Impact factor: 4.142

3.  Solvent Retention Capacity and Gluten Protein Composition of Durum Wheat Flour as Influenced by Drought and Heat Stress.

Authors:  Maryke Labuschagne; Carlos Guzmán; Keneuoe Phakela; Barend Wentzel; Angeline van Biljon
Journal:  Plants (Basel)       Date:  2021-05-17

4.  Coupling Multi Angle Light Scattering to Ion Exchange chromatography (IEX-MALS) for protein characterization.

Authors:  Hadar Amartely; Orly Avraham; Assaf Friedler; Oded Livnah; Mario Lebendiker
Journal:  Sci Rep       Date:  2018-05-02       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.