Literature DB >> 27913947

Preclinical Evaluation of Cathepsin-Based Fluorescent Imaging System for Cytoreductive Surgery.

Carlos H F Chan1,2, Lukas F Liesenfeld3, Isabel Ferreiro-Neira3, James C Cusack4.   

Abstract

BACKGROUND: Cytoreductive surgery and hyperthermic intraperitoneal chemotherapy (CRS-HIPEC) is a treatment option for peritoneal surface malignancies. The ability to detect microscopic foci of peritoneal metastasis intraoperatively may ensure the completeness of cytoreduction. In this study, we evaluated the suitability of a hand-held cathepsin-based fluorescent imaging system for intraoperative detection of appendiceal and colorectal peritoneal metastasis.
METHODS: Peritoneal tumors and normal peritoneal tissues were collected from patients with appendiceal and colorectal peritoneal metastasis. Expression of different cathepsins (CTS-B, -D, -F, -G, -K, -L, -O, and -S) was determined by quantitative RT-PCR and immunohistochemistry. The hand-held cathepsin-based fluorescent imaging system was used to detect peritoneal xenografts derived from human colon cancer cells (HT29, LoVo and HCT116) in nu/nu mice.
RESULTS: While the expression levels of CTS-B, -D, -L, and -S could be higher in peritoneal tumors than normal peritoneum with a median (range) of 6.1 (2.9-25.8), 2.0 (1.0-15.8), 1.4 (0.8-7.0), and 2.1 (1.6-13.9) folds by quantitative RT-PCR, respectively, CTS-B was consistently the major contributor of the overall cathepsin expression in appendiceal and colonic peritoneal tumors, including adenocarcinomas and low-grade appendiceal mucinous neoplasms. Using peritoneal xenograft mouse models, small barely visible colonic peritoneal tumors (<2.5 mm in maximum diameter) could be detected by the hand-held cathepsin-based fluorescent imaging system.
CONCLUSIONS: Because cathepsin expression is higher in peritoneal tumors than underlying peritoneum, the hand-held cathepsin-based fluorescent imaging system could be useful for intraoperative detection of microscopic peritoneal metastasis during CRS-HIPEC and clinical trial is warranted.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27913947     DOI: 10.1245/s10434-016-5690-5

Source DB:  PubMed          Journal:  Ann Surg Oncol        ISSN: 1068-9265            Impact factor:   5.344


  3 in total

1.  ASO Author Reflections: Robust Prediction Models for Colon Cancer in Asian Patients.

Authors:  Amrita Chattopadhyay; Tzu-Pin Lu
Journal:  Ann Surg Oncol       Date:  2021-08-26       Impact factor: 5.344

2.  Indocyanine green fluorescence-guided intraoperative detection of peritoneal carcinomatosis: systematic review.

Authors:  Gian Luca Baiocchi; Federico Gheza; Sarah Molfino; Luca Arru; Marco Vaira; Simone Giacopuzzi
Journal:  BMC Surg       Date:  2020-07-17       Impact factor: 2.102

3.  Performance of a novel protease-activated fluorescent imaging system for intraoperative detection of residual breast cancer during breast conserving surgery.

Authors:  Conor R Lanahan; Bridget N Kelly; Michele A Gadd; Michelle C Specht; Carson L Brown; Kevin S Hughes; Rong Tang; Upahvan Rai; Elena F Brachtel; Travis Rice-Stitt; Barbara L Smith
Journal:  Breast Cancer Res Treat       Date:  2021-02-21       Impact factor: 4.872

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.