Literature DB >> 27913377

Optimization and Assessment of Three Different High Performance Liquid Chromatographic Systems for the Combinative Fingerprint Analysis and Multi-Ingredients Quantification of Sangju Ganmao Tablet.

Meng-Zhe Guo1,2, Jie Han1, Dan-Dan He1, Jia-Hui Zou1, Zheng Li1, Yan Du1,2, Dao-Quan Tang1,2.   

Abstract

Chromatographic separation is still a critical subject for the quality control of traditional Chinese medicine. In this study, three different high performance liquid chromatographic (HPLC) systems employing commercially available columns packed with 1.8, 3.5 and 5.0 μm particles were respectively developed and optimized for the combinative fingerprint analysis and multi-ingredients quantification of Sangju Ganmao tablet (SGT). Chromatographic parameters including the repeatability of retention time and peak area, symmetry factor, resolution, number of theoretical plates and peak capacity were used to assess the chromatographic performance of different HPLC systems. The optimal chromatographic system using Agilent ZORBAX SB-C18 column (2.1 mm × 100 mm, 3.5 μm) as stationary phase was respectively coupled with diode array detector or mass spectrometry detector for the chromatographic fingerprint analysis and simultaneous quantification or identification of nine compounds of SGT. All the validation data conformed to the acceptable requirements. For the fingerprint analysis, 31 peaks were selected as the common peaks to evaluate the similarities of SGT from 10 different manufacturers using heatmap, hierarchical cluster analysis and principal component analysis. The results demonstrated that the combinations of the quantitative and chromatographic fingerprint analysis offer an efficient way to evaluate the quality consistency of SGT.
© The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Mesh:

Substances:

Year:  2017        PMID: 27913377     DOI: 10.1093/chromsci/bmw190

Source DB:  PubMed          Journal:  J Chromatogr Sci        ISSN: 0021-9665            Impact factor:   1.618


  1 in total

1.  Chemical Profiling and Comparison of Sangju Ganmao Tablet and Its Component Herbs Using Two-Dimensional Liquid Chromatography to Explore Compatibility Mechanism of Herbs.

Authors:  Shuai Ji; Zhan-Zhong Liu; Jing Wu; Yan Du; Zhen-Yu Su; Tian-Yun Wang; Jie Han; Dong-Zhi Yang; Meng-Zhe Guo; Dao-Quan Tang
Journal:  Front Pharmacol       Date:  2018-10-16       Impact factor: 5.810

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.