Literature DB >> 27910829

Optimization of photon beam energies in gold nanoparticle enhanced arc radiation therapy using Monte Carlo methods.

B Koger1, C Kirkby.   

Abstract

As a recent area of development in radiation therapy, gold nanoparticle (GNP) enhanced radiation therapy has shown potential to increase tumour dose while maintaining acceptable levels of healthy tissue toxicity. In this study, the effect of varying photon beam energy in GNP enhanced arc radiation therapy (GEART) is quantified through the introduction of a dose scoring metric, and GEART is compared to a conventional radiotherapy treatment. The PENELOPE Monte Carlo code was used to model several simple phantoms consisting of a spherical tumour containing GNPs (concentration: 15 mg Au g-1 tumour, 0.8 mg Au g-1 normal tissue) in a cylinder of tissue. Several monoenergetic photon beams, with energies ranging from 20 keV to 6 MeV, as well as 100, 200, and 300 kVp spectral beams, were used to irradiate the tumour in a 360° arc treatment. A dose metric was then used to compare tumour and tissue doses from GEART treatments to a similar treatment from a 6 MV spectrum. This was also performed on a simulated brain tumour using patient computed tomography data. GEART treatments showed potential over the 6 MV treatment for many of the simulated geometries, delivering up to 88% higher mean dose to the tumour for a constant tissue dose, with the effect greatest near a source energy of 50 keV. This effect is also seen with the inclusion of bone in a brain treatment, with a 14% increase in mean tumour dose over 6 MV, while still maintaining acceptable levels of dose to the bone and brain.

Entities:  

Year:  2016        PMID: 27910829     DOI: 10.1088/1361-6560/61/24/8839

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Energy optimization in gold nanoparticle enhanced radiation therapy.

Authors:  Wonmo Sung; Jan Schuemann
Journal:  Phys Med Biol       Date:  2018-06-25       Impact factor: 3.609

2.  Intercomparison of Monte Carlo calculated dose enhancement ratios for gold nanoparticles irradiated by X-rays: Assessing the uncertainty and correct methodology for extended beams.

Authors:  H Rabus; W B Li; C Villagrasa; J Schuemann; P A Hepperle; L de la Fuente Rosales; M Beuve; S Di Maria; A P Klapproth; C Y Li; F Poignant; B Rudek; H Nettelbeck
Journal:  Phys Med       Date:  2021-03-23       Impact factor: 2.685

3.  Impact of the Spectral Composition of Kilovoltage X-rays on High-Z Nanoparticle-Assisted Dose Enhancement.

Authors:  Maria A Kolyvanova; Alexandr V Belousov; Grigorii A Krusanov; Alexandra K Isagulieva; Kirill V Morozov; Maria E Kartseva; Magomet H Salpagarov; Pavel V Krivoshapkin; Olga V Dement'eva; Victor M Rudoy; Vladimir N Morozov
Journal:  Int J Mol Sci       Date:  2021-06-02       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.