Literature DB >> 27909130

The use of ultra-low-dose CT scans for the evaluation of limb fractures: is the reduced effective dose using ct in orthopaedic injury (REDUCTION) protocol effective?

S R Konda1, A M Goch2, P Leucht3, A Christiano4, S Gyftopoulos5, G Yoeli6, K A Egol1.   

Abstract

AIMS: To evaluate whether an ultra-low-dose CT protocol can diagnose selected limb fractures as well as conventional CT (C-CT). PATIENTS AND METHODS: We prospectively studied 40 consecutive patients with a limb fracture in whom a CT scan was indicated. These were scanned using an ultra-low-dose CT Reduced Effective Dose Using Computed Tomography In Orthopaedic Injury (REDUCTION) protocol. Studies from 16 selected cases were compared with 16 C-CT scans matched for age, gender and type of fracture. Studies were assessed for diagnosis and image quality. Descriptive and reliability statistics were calculated. The total effective radiation dose for each scanned site was compared.
RESULTS: The mean estimated effective dose (ED) for the REDUCTION protocol was 0.03 milliSieverts (mSv) and 0.43 mSv (p < 0.005) for C-CT. The sensitivity (Sn), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV) of the REDUCTION protocol to detect fractures were 0.98, 0.89, 0.98 and 0.89 respectively when two occult fractures were excluded. Inter- and intra-observer reliability for diagnosis using the REDUCTION protocol (κ = 0.75, κ = 0.71) were similar to those of C-CT (κ = 0.85, κ = 0.82). Using the REDUCTION protocol, 3D CT reconstructions were equivalent in quality and diagnostic information to those generated by C-CT (κ = 0.87, κ = 0.94).
CONCLUSION: With a near 14-fold reduction in estimated ED compared with C-CT, the REDUCTION protocol reduces the amount of CT radiation substantially without significant diagnostic decay. It produces images that appear to be comparable with those of C-CT for evaluating fractures of the limbs. Cite this article: Bone Joint J 2016;98-B:1668-73. ©2016 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Computed tomography; Extremity; Fracture; Low dose

Mesh:

Year:  2016        PMID: 27909130     DOI: 10.1302/0301-620X.98B12.BJJ-2016-0336.R1

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  9 in total

1.  MDCT-based Finite Element Analysis of Vertebral Fracture Risk: What Dose is Needed?

Authors:  D Anitha; Kai Mei; Michael Dieckmeyer; Felix K Kopp; Nico Sollmann; Claus Zimmer; Jan S Kirschke; Peter B Noel; Thomas Baum; Karupppasamy Subburaj
Journal:  Clin Neuroradiol       Date:  2018-08-21       Impact factor: 3.649

2.  Ultra-low-dose CT versus radiographs for minor spine and pelvis trauma: a Bayesian analysis of accuracy.

Authors:  Aymeric Hamard; Joel Greffier; Sophie Bastide; Ahmed Larbi; Takieddine Addala; Alexandre Sadate; Jean-Paul Beregi; Julien Frandon
Journal:  Eur Radiol       Date:  2020-10-09       Impact factor: 5.315

3.  The added value of cross-sectional imaging in the detection of additional radiographically occult fractures in the setting of a Chopart fracture.

Authors:  Renata R Almeida; Mohammad Mansouri; David K Tso; Anne H Johnson; Michael H Lev; Ajay K Singh; Efren J Flores
Journal:  Emerg Radiol       Date:  2018-06-06

4.  Radiation Dose Reduction of Computed Tomography in Complex Distal Femur Fractures: A Cadaver Study to Develop a Low Dose Scanning Protocol.

Authors:  Nicholas O'Neill; Samuel J Wisniewski; Michael Adams; James Peters; Michael Wagner
Journal:  Spartan Med Res J       Date:  2019-07-01

5.  Ultra-low dose CT for scaphoid fracture detection-a simulational approach to quantify the capability of radiation exposure reduction without diagnostic limitation.

Authors:  Gabriel Keller; Florian Hagen; Leoni Neubauer; Katarzyna Rachunek; Fabian Springer; Mareen Sarah Kraus
Journal:  Quant Imaging Med Surg       Date:  2022-09

6.  Early results of ultra-low-dose CT-scan for extremity traumas in emergency room.

Authors:  Taki Eddine Addala; Joël Greffier; Aymeric Hamard; Fehmi Snene; Xavier Bobbia; Sophie Bastide; Asmaa Belaouni; Hélène de Forges; Ahmed Larbi; Jean-Emmanuel de la Coussaye; Jean-Paul Beregi; Pierre-Géraud Claret; Julien Frandon
Journal:  Quant Imaging Med Surg       Date:  2022-08

7.  3D cone-beam CT with a twin robotic x-ray system in elbow imaging: comparison of image quality to high-resolution multidetector CT.

Authors:  Jan-Peter Grunz; Andreas Max Weng; Andreas Steven Kunz; Maike Veyhl-Wichmann; Rainer Schmitt; Carsten Herbert Gietzen; Lenhard Pennig; Stefan Herz; Süleyman Ergün; Thorsten Alexander Bley; Tobias Gassenmaier
Journal:  Eur Radiol Exp       Date:  2020-09-08

8.  Ultra-low-dose CT for extremities in an acute setting: initial experience with 203 subjects.

Authors:  Zlatan Alagic; Robert Bujila; Anders Enocson; Subhash Srivastava; Seppo K Koskinen
Journal:  Skeletal Radiol       Date:  2019-09-09       Impact factor: 2.199

9.  Unilateral-dominant reduction in muscle volume in female knee osteoarthritis patients: computed tomography-based analysis of bilateral sides.

Authors:  Ayumi Tsukada; Kentaro Uchida; Jun Aikawa; Shotaro Takano; Dai Iwase; Manabu Mukai; Masayuki Miyagi; Yuta Nanri; Gen Inoue; Masashi Takaso
Journal:  J Orthop Surg Res       Date:  2020-11-19       Impact factor: 2.359

  9 in total