A Meta-analysis of Functional Outcomes in Patient-Specific Instrumented Knee Arthroplasty.

Ashim Mannan1, Deji Akinyooye1, Fahad Hossain1.   

Abstract

Alignment data in patient-specific instrumented (PSI) knee arthroplasty have been examined in several meta-analyses, with demonstration of comparative but not improved restitution of a neutral mechanical axis and favorable outcomes in femoral implant axial alignment. To date, no comprehensive synthesis of data has been conducted specifically for functional outcomes. Relevant databases were searched according to Preferred Reporting Items for Systematic reviews and Meta-analyses guidelines during the period 2000 to 2015 of Levels 1 and 2 studies comparing functional outcomes of patient-specific instrumentation (PSI) versus conventional instrumentation. Outcomes of interest included postoperative Knee Society score (KSS) (function), KSS (knee), range of movement (ROM), Oxford knee scores (OKS), and Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores. Five randomized controlled trials and three prospective-comparative studies were included reporting on a total of 828 knees. All eight studies reported postoperative KSS (function) and seven studies reported KSS (knee). Three studies reported postoperative OKS, four documented ROM, and two reported WOMAC scores. Meta-analysis demonstrated equivalent KSS (function) scores 3 months postsurgery (Z = 1.71, p = 0.09). In addition, no significant differences were found for KSS (function) at 6 months (Z = 0.51, p = 0.61) or 12 to 24 months postsurgery (Z = 0.05, p = 0.96). In addition, no significant differences were found between PSI and conventional instrumentation for postoperative KSS (knee), ROM, or OKS. In summary, this systematic review and meta-analysis demonstrates no conclusive evidence for or against PSI when considering short-term functional outcomes. Further high-quality studies are required to investigate both mid- and long-term outcomes as well as survivorship data. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Year:  2016        PMID: 27907935     DOI: 10.1055/s-0036-1593869

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  8 in total

1.  Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial.

Authors:  Nienke M Kosse; Petra J C Heesterbeek; Janneke J P Schimmel; Gijs G van Hellemondt; Ate B Wymenga; Koen C Defoort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-11-28       Impact factor: 4.342

2.  Mid-term functional outcomes of patient-specific versus conventional instrumentation total knee arthroplasty: a prospective study.

Authors:  Vikaesh Moorthy; Jerry Yongqiang Chen; Ming Han Lincoln Liow; Pak Lin Chin; Shi-Lu Chia; Ngai Nung Lo; Seng Jin Yeo
Journal:  Arch Orthop Trauma Surg       Date:  2021-01-02       Impact factor: 3.067

Review 3.  Navigation and robotics improved alignment compared with PSI and conventional instrument, while clinical outcomes were similar in TKA: a network meta-analysis.

Authors:  Kai Lei; LiMing Liu; Xin Chen; Qing Feng; Liu Yang; Lin Guo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-01-25       Impact factor: 4.114

Review 4.  Patient-Specific or Conventional Instrumentations: A Meta-analysis of Randomized Controlled Trials.

Authors:  Yipeng Lin; Wufeng Cai; Baoyun Xu; Jian Li; Yuan Yang; Xuelin Pan; Weili Fu
Journal:  Biomed Res Int       Date:  2020-03-10       Impact factor: 3.411

5.  Functional outcomes in patient specific instrumentation vs. conventional instrumentation for total knee arthroplasty; a systematic review and meta-analysis of prospective studies.

Authors:  Branavan Rudran; Henry Magill; Nikhil Ponugoti; Andy Williams; Simon Ball
Journal:  BMC Musculoskelet Disord       Date:  2022-07-23       Impact factor: 2.562

6.  Clinical outcomes after using patient specific instrumentation: is it worth the effort? A minimum 5-year retrospective review of 298 PSI knees.

Authors:  Luke Nugent; Sarang Kasture; Muthu Ganapathi
Journal:  Arch Orthop Trauma Surg       Date:  2022-10-10       Impact factor: 2.928

7.  Are There Differences in Accuracy or Outcomes Scores Among Navigated, Robotic, Patient-specific Instruments or Standard Cutting Guides in TKA? A Network Meta-analysis.

Authors:  Pierre-Alban Bouché; Simon Corsia; Agnès Dechartres; Matthieu Resche-Rigon; Rémy Nizard
Journal:  Clin Orthop Relat Res       Date:  2020-09       Impact factor: 4.755

8.  Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis.

Authors:  Kazuha Kizaki; Ajaykumar Shanmugaraj; Fumiharu Yamashita; Nicole Simunovic; Andrew Duong; Vickas Khanna; Olufemi R Ayeni
Journal:  BMC Musculoskelet Disord       Date:  2019-11-23       Impact factor: 2.362