Literature DB >> 2789971

Climate, intermittent humidification, and humidifier fever.

K Anderson1, A D Watt, D Sinclair, C Lewis, C P McSharry, G Boyd.   

Abstract

Two summer outbreaks of humidifier fever (HF) are described in a microprocessor factory (factory A) and a printing factory (factory B). The air in each factory was humidified intermittently and controlled by present humidistats operating to maintain a relative humidity of 45% by an air handler incorporating a spray humidifier in factory A and two ceiling mounted spray humidifiers in factory B. Questionnaire data from each workforce suggested that although symptoms apparently occurred most commonly in both factories on return from holiday (41/57, 71.9%), many subjects (24/40, 60%) in factory A also had intermittent symptoms of ill defined periodicity for some time before the disorder was recognised. Similar intermittent symptoms with no discernible pattern occurred in factory B in a smaller number of subjects (4/17, 23.5%), all of whom were night or rotating shift workers. Both episodes of humidifier fever after return from summer holiday developed when nocturnal air temperatures were unseasonably low; not on the day of return to work but two days later (factory A) and one day later (factory B). Symptoms were most common in most workers who had circulating serum IgG antibody measured by ELISA to humidifier sludge in factory B (14/17, 82.9%) but were most common in IgG antibody negative subjects in factory A (27/40, 67.5%). A more classic form of humidifier fever redeveloped in factory B during winter when meteorological recordings suggested that humidification of intake air was more continuous. Humidifier fever in winter may have been the major influence on the formulation of the symptom pattern thought to be relevant for recognition of the disorder. A form of the illness, however, can occur during the summer which is camouflaged by intermittent humidification when the symptoms appear to be more closely associated with cool nocturnal air intake and unrelated to the pattern of attendance at work.

Entities:  

Mesh:

Year:  1989        PMID: 2789971      PMCID: PMC1009844          DOI: 10.1136/oem.46.9.671

Source DB:  PubMed          Journal:  Br J Ind Med        ISSN: 0007-1072


  9 in total

1.  [Febrile group diseases in a carpentry shop caused by inhalation of moisture from air humidifiers contaminated with molds].

Authors:  C PESTALOZZI
Journal:  Schweiz Med Wochenschr       Date:  1959-07-04

2.  Extrinsic allergic alveolitis caused by a cold water humidifier.

Authors:  A S Robertson; P S Burge; G A Wieland; M H Carmalt
Journal:  Thorax       Date:  1987-01       Impact factor: 9.139

3.  Hypersensitivity pneumonitis due to contamination of an air conditioner.

Authors:  E F Banaszak; W H Thiede; J N Fink
Journal:  N Engl J Med       Date:  1970-08-06       Impact factor: 91.245

Review 4.  Building related illness.

Authors:  M J Finnegan; C A Pickering
Journal:  Clin Allergy       Date:  1986-09

5.  Organic dust toxicity (pulmonary mycotoxicosis) associated with silo unloading.

Authors:  J J May; L Stallones; D Darrow; D S Pratt
Journal:  Thorax       Date:  1986-12       Impact factor: 9.139

6.  Serological and clinical investigation of humidifier fever.

Authors:  C McSharry; K Anderson; G Boyd
Journal:  Clin Allergy       Date:  1987-01

7.  Extrinsic allergic alveolitis and contaminated cooling-water in a factory machine.

Authors:  J A Friend; J Gaddie; K N Palmer; C A Pickering; J Pepys
Journal:  Lancet       Date:  1977-02-05       Impact factor: 79.321

8.  Radiographic changes in humidifier fever.

Authors:  K Anderson; C P McSharry; G Boyd
Journal:  Thorax       Date:  1985-04       Impact factor: 9.139

9.  Occupational asthma in a factory with a contaminated humidifier.

Authors:  P S Burge; M Finnegan; N Horsfield; D Emery; P Austwick; P S Davies; C A Pickering
Journal:  Thorax       Date:  1985-04       Impact factor: 9.139

  9 in total
  3 in total

1.  Health complaints and immunological markers of exposure to bioaerosols among biowaste collectors and compost workers.

Authors:  J Bünger; M Antlauf-Lammers; T G Schulz; G A Westphal; M M Müller; P Ruhnau; E Hallier
Journal:  Occup Environ Med       Date:  2000-07       Impact factor: 4.402

2.  Sump bay fever: inhalational fever associated with a biologically contaminated water aerosol.

Authors:  K Anderson; C P McSharry; C Clark; C J Clark; G R Barclay; G P Morris
Journal:  Occup Environ Med       Date:  1996-02       Impact factor: 4.402

3.  Discriminant analysis of symptom pattern and serum antibody titres in humidifier related disease.

Authors:  C McSharry; K Anderson; A Speekenbrink; C Lewis; G Boyd
Journal:  Thorax       Date:  1993-05       Impact factor: 9.139

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.