Literature DB >> 27897461

Stability Development of Immediately Loaded Hybrid Self-Tapping Implants Inserted in the Posterior Maxilla: 1-Year Results of a Randomized Controlled Trial.

Vladimir S Todorovic1,2, Miroslav Vasovic3, Mia-Michaela Beetge2, Andre W van Zyl2, Vladimir Kokovic4.   

Abstract

The objective of the present study was to elucidate stability development of immediately loaded hybrid self-tapping implants inserted in the posterior maxilla. Forty-eight hybrid self-tapping implants with a chemically modified surface (∅4.1; length: 8 mm) were inserted bilaterally in the maxillary first and second premolar and first molar sites of 8 patients. In each patient, both sides of the maxilla were assigned randomly to either immediate (IL) or early (EL) loading group. Implant stability was evaluated by means of resonance frequency analysis immediately after implant placement and after 1, 2, 3, 4, 5, 6, 12, 26, and 52 weeks. High values of primary stability were found in both groups (71.91 ± 6.52 implant stability quotient [ISQ] in IL group; 73.87 ± 6.5 ISQ in EL group), with significant differences between the groups at the different time points. Initial decrease in stability was observed between the first and fifth weeks in the IL group and between the first and third weeks for the EL group. In the IL group 1 implant was removed after 3 weeks due to lack of stability. Early results of this study showed the ability of hybrid self-tapping dental implants with a chemically modified surface to achieve sufficient primary stability and to maintain high values of secondary implant stability in bone type 3 and 4, even when loaded immediately. Minimal alterations in stability were observed for both investigated groups, but the EL group showed faster recovery after an initial drop in stability.

Entities:  

Keywords:  hybrid self-tapping dental implants; immediate loading; implant stability; posterior maxilla

Mesh:

Substances:

Year:  2016        PMID: 27897461     DOI: 10.1563/aaid-joi-D-16-00143

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  2 in total

1.  Topical Delivery of Carvedilol Loaded Nano-Transfersomes for Skin Cancer Chemoprevention.

Authors:  Mengbing Chen; Md Abdullah Shamim; Ayaz Shahid; Steven Yeung; Bradley T Andresen; Jeffrey Wang; Vijaykumar Nekkanti; Frank L Meyskens; Kristen M Kelly; Ying Huang
Journal:  Pharmaceutics       Date:  2020-11-27       Impact factor: 6.321

2.  Comparison of sandblasted and acid-etched surface implants and new hydrophilic surface implants in the posterior maxilla using a 3-month early-loading protocol: a randomized controlled trial.

Authors:  Hyeong Gi Kim; Pil-Young Yun; Young-Kyun Kim; Il-Hyung Kim
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2021-06-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.