Literature DB >> 27897352

Functional magnetic resonance imaging for in vivo quantification of pulmonary hypertension in the Sugen 5416/hypoxia mouse.

Ellen C Breen1, Miriam Scadeng2, N Chin Lai3, Fiona Murray4, Timothy D Bigby1,3.   

Abstract

NEW
FINDINGS: What is the central question of this study? Non-invasive, quantitative methods to assess right cardiac function in mice with pulmonary hypertension have not been demonstrated. What is the main finding and its importance? This study shows the potential of magnetic resonance imaging to estimate right ventricular ejection fraction and measure spatial, dynamic changes in cardiac structure in the Sugen 5416/hypoxia mouse model of pulmonary hypertension. Pulmonary arterial hypertension (PAH) is characterized by elevated pulmonary artery pressures and right heart failure. Mouse models of PAH are instrumental in understanding the disease pathophysiology. However, few methods are available to evaluate right cardiac function in small animals. In this study, magnetic resonance imaging was used to measure in vivo cardiac dimensions in the Sugen 5416/hypoxia mouse model. Pulmonary hypertension (PH) was induced in C57BL/6 mice by 3 weeks of exposure to 10% oxygen and vascular endothelial growth factor receptor inhibition (20 mg kg-1 SU5416). Control mice were housed in room air and received vehicle (DMSO). Right ventricular pressures were recorded with a pressure-conductance transducer. Short-axis contiguous 1-mm-thick slices were acquired through the heart and great vessels using a fast low-angle shot (FLASH)-cine sequence. Thirteen images were collected throughout each cardiac cycle. Right ventricular systolic pressure was elevated in PH mice (23.6 ± 6 versus 41.0 ± 11 mmHg, control versus PH, respectively; P < 0.001, n = 5-11). Right ventricular wall thickness was greater in PH than in control mice at end diastole (0.30 ± 0.05 versus 0.48 ± 0.06 mm, control versus PH, respectively; P < 0.01, n = 6), but measurements were not different at end systole (control versus PH, 0.59 ± 0.11 versus 0.70 ± 0.11 mm, respectively). Right ventricular ejection fraction was decreased in PH mice (72 ± 3 versus 58 ± 5%, control versus PH, respectively; P < 0.04, n = 6). These data demonstrate that magnetic resonance imaging is a precise method to monitor right ventricular remodelling and cardiac output longitudinally in mouse models of PH.
© 2016 The Authors. Experimental Physiology © 2016 The Physiological Society.

Entities:  

Keywords:  hypoxia; magnetic resonance; pulmonary hypertension

Mesh:

Substances:

Year:  2017        PMID: 27897352     DOI: 10.1113/EP086067

Source DB:  PubMed          Journal:  Exp Physiol        ISSN: 0958-0670            Impact factor:   2.969


  4 in total

1.  CrossTalk opposing view: The mouse SuHx model is not a good model of pulmonary arterial hypertension.

Authors:  Sally H Vitali
Journal:  J Physiol       Date:  2018-11-29       Impact factor: 5.182

2.  Long-term pulmonary and cardiovascular morbidities of neonatal hyperoxia exposure in mice.

Authors:  Renuka T Menon; Amrit Kumar Shrestha; Corey L Reynolds; Roberto Barrios; Binoy Shivanna
Journal:  Int J Biochem Cell Biol       Date:  2017-12-07       Impact factor: 5.085

3.  IL-33/ST2 receptor-dependent signaling in the development of pulmonary hypertension in Sugen/hypoxia mice.

Authors:  Cynthia S Indralingam; Alma K Gutierrez-Gonzalez; Scott C Johns; Tzuhan Tsui; Daniel T Cannon; Mark M Fuster; Timothy D Bigby; Patricia A Jennings; Ellen C Breen
Journal:  Physiol Rep       Date:  2022-02

4.  Exploring the failing right ventricle in pulmonary hypertension by cardiac magnetic resonance: An in vivo study utilizing Macitentan.

Authors:  Gerard Murphy; Geeshath Jayasekera; James Mullin; Lindsay Gallagher; David J Welsh
Journal:  Pulm Circ       Date:  2022-07-01       Impact factor: 2.886

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.