Incidence of breast implant rupture in a 12-year retrospective cohort: Evidence of quality discrepancy depending on the range.

Frédéric Seigle-Murandi1, François Lefebvre2, Catherine Bruant-Rodier3, Frédéric Bodin3.   

Abstract

BACKGROUND &
OBJECTIVE: The majority of studies assessing the rupture rate of breast implants were performed by the breast implant manufacturing industry with questionable independence. After repetitive removals of ruptured implants from the same model, our team decided to assess the rupture rate and the estimated risk thereof for most of the silicone gel-filled implants we have used since they regained market approval in France in 2001.
METHODS: Our study is a retrospective cohort of 809 patients operated in our University Hospital from 2001 to 2013 for cosmetic or reconstructive goals. We could track 1561 implants, 90% of them from the same manufacturer, Allergan (Irvine, CA, USA). For each of those, we gathered their exact reference, date of implantation, surgical approach, status, last follow-up visit or the eventual date, and cause of removal.
RESULTS: Of 225 explanted devices, only 27 were ruptured, all from the Allergan brand. Risks of removal for rupture were estimated: 0.5% at 1000 days, 6% at 2000 days, and 14% at 3000 days. Risks were significantly different between the models from this same manufacturer. One of the range of macro-textured round implants showed risks of removal for rupture of 33% at 3000 days compared to 6% for the anatomically shaped range.
CONCLUSIONS: These results suggest a qualitative discrepancy among the different ranges of breast implants of a single manufacturer within the same timeframe of implantation. To determine the in vivo lifespan of the implants that we use more precisely and sooner, we suggest that each removed implant should be analyzed for wear and tear, independently from the industry.
Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Breast implants; Medical device vigilance; Rupture; Silicone

Mesh:

Substances:

Year:  2016        PMID: 27894917     DOI: 10.1016/j.bjps.2016.11.001

Source DB:  PubMed          Journal:  J Plast Reconstr Aesthet Surg        ISSN: 1748-6815            Impact factor:   2.740


  4 in total

1.  Silicone breast implants and depression, fibromyalgia and chronic fatigue syndrome in a rheumatology clinic population.

Authors:  Thomas Khoo; Susanna Proudman; Vidya Limaye
Journal:  Clin Rheumatol       Date:  2019-01-31       Impact factor: 2.980

2.  Management of a late breast implant rupture in the setting of previous radiation.

Authors:  Vanessa E Molinar; Mohamed Diya Sabbagh; Oscar J Manrique
Journal:  BMJ Case Rep       Date:  2018-06-04

3.  Subjective Cognitive Functioning in Silicone Breast Implant Patients: A Cohort Study.

Authors:  Maartje J L Colaris; Jan Willem Cohen Tervaert; Rudolf W H M Ponds; Johan Wilmink; Rene R W J van der Hulst
Journal:  Plast Reconstr Surg Glob Open       Date:  2021-02-17

4.  Diagnostic value of a spiral breast computed tomography system equipped with photon counting detector technology in patients with implants: An observational study of our initial experiences.

Authors:  Lisa Ruby; Sojin Shim; Nicole Berger; Magda Marcon; Thomas Frauenfelder; Andreas Boss
Journal:  Medicine (Baltimore)       Date:  2020-07-24       Impact factor: 1.817

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.