| Literature DB >> 27894284 |
Ting-Tse Lin1, Yen-Ling Sung2, Chih-En Wu2, Hong Zhang3, Yen-Bin Liu1, Shien-Fong Lin4.
Abstract
BACKGROUNDS: Patients with rheumatoid arthritis (RA) have increased risk of sudden cardiac death (SCD), which is two-fold higher than general population. The driving cause of SCD was considered due to lift-threatening arrhythmia where systemic inflammation acts as the pathophysiological basis linking RA to autonomicdysfunction.Entities:
Keywords: Autonomic function; Collagen-induced arthritis; Deceleration capacity; Heart rate variability; Rheumatoid arthritis
Mesh:
Substances:
Year: 2016 PMID: 27894284 PMCID: PMC5127040 DOI: 10.1186/s12891-016-1347-6
Source DB: PubMed Journal: BMC Musculoskelet Disord ISSN: 1471-2474 Impact factor: 2.362
Fig. 1Macroscopic observation of joint swelling in collagen-induced arthritis (CIA) rats. a Normal rats. b Induced arthritis on day 20 of CIA rats. c The severity of arthritis in clinical scoring. d The severity of arthritis in paw thickness. Differences between the control group and the model group were statistically significant (p < 0.05)
Comparison of HRV parameter between CIA rats and controls 1st week to 6th week
| 1st week | 2nd week | 3rd week | 4th week | 5th week | 6th week | ||
|---|---|---|---|---|---|---|---|
| Linear HRV parameters | |||||||
| Mean HR | Control | 386 ± 25 | 411 ± 57 | 411 ± 6 | 377 ± 21 | 375 ± 18 | 378 ± 25 |
| CIA | 458 ± 35* | 438 ± 31* | 471 ± 31* | 493 ± 4* | 383 ± 21 | 380 ± 28 | |
| SDNN(ms) | Control | 4.53 ± 2.5 | 6.08 ± 3.4 | 3.9 ± 0.9 | 3.55 ± 1.3 | 3.89 ± 1.4 | 3.21 ± 1.3 |
| CIA | 8.23 ± 1.6* | 12.28 ± 4.3* | 5.82 ± 2.7* | 4.31 ± 1.0 | 5.26 ± 3.4 | 3.21 ± 1.3 | |
| RMSSD(ms) | Control | 3.03 ± 0.8 | 3.35 ± 1.4 | 2.37 ± 0.2 | 2.72 ± 0.5 | 2.81 ± 0.5 | 2.62 ± 0.5 |
| CIA | 3.37 ± 0.7 | 3.13 ± 0.5 | 2.73 ± 0.6 | 2.4 ± 0.1 | 2.44 ± 0.2 | 2.41 ± 0.1 | |
| LF(n.u) | Control | 61.71 ± 9.3 | 60.02 ± 7.2 | 62.73 ± 11.1 | 60.29 ± 8.5 | 61.59 ± 7.9 | 59.01 ± 9.3 |
| CIA | 69.48 ± 5.7* | 68.41 ± 5.1* | 68.78 ± 10.1* | 57.89 ± 12.7 | 52.13 ± 16.1 | 49.73 ± 16.3 | |
| HF(n.u) | Control | 38.01 ± 9.1 | 39.85 ± 7.2 | 37.13 ± 11 | 39.38 ± 8.4 | 38.11 ± 7.9 | 40.66 ± 9.1 |
| CIA | 30.34 ± 5.6* | 31.46 ± 5.0* | 40.93 ± 10.1 | 41.77 ± 12.6 | 47.46 ± 15.9 | 49.94 ± 16.2 | |
| LF/HF | Control | 1.76 ± 0.6 | 1.58 ± 0.5 | 1.9 ± 0.9 | 1.65 ± 0.6 | 1.73 ± 0.6 | 1.56 ± 0.6 |
| CIA | 2.41 ± 0.7* | 2.24 ± 0.5* | 1.68 ± 0.4 | 1.60 ± 0.8 | 1.31 ± 0.7 | 1.2 ± 0.8 | |
| Non-linear HRV parameters | |||||||
| DFA:α1 | Control | 0.62 ± 0.2 | 0.74 ± 0.3 | 0.69 ± 0.1 | 0.47 ± 0.1 | 0.49 ± 0.1 | 0.51 ± 0.1 |
| CIA | 0.88 ± 0.2* | 0.82 ± 0.2* | 0.7 ± 0.3 | 0.43 ± 0.1 | 0.53 ± 0.1 | 0.52 ± 0.1 | |
| DFA:α2 | Control | 0.71 ± 0.4 | 1.09 ± 0.3 | 0.84 ± 0.1 | 0.79 ± 0.3 | 0.65 ± 0.2 | 0.52 ± 0.3 |
| CIA | 1.12 ± 0.1+ | 1.24 ± 0.1* | 0.81 ± 0.1 | 0.78 ± 0.1 | 0.62 ± 0.3 | 0.51 ± 0.3 | |
| DC(ms) | Control | 13.7 ± 2.7 | 11.1 ± 3.8 | 9.2 ± 0.7 | 9.6 ± 2.9 | 8.2 ± 1.4 | 8.5 ± 3.5 |
| CIA | 9.5 ± 2.4* | 9.8 ± 2.6* | 7.5 ± 2.8* | 6.9 ± 1.1* | 6.9 ± 1.6* | 7.3 ± 2.2* | |
| AC(ms) | Control | –10.6 ± 2.4 | –8.1 ± 6.3 | –5.2 ± 0.4 | –7.3 ± 2.7 | –6.1 ± 1.4 | –6.3 ± 3.1 |
| CIA | –7.1 ± 2.6* | –7.7 ± 2.0 | –4.1 ± 3.1 | –4.8 ± 0.9* | –5.7 ± 1.7 | –5.2 ± 1.8 | |
*p < 0.05 when compared with control group using independent-samples t test
Fig. 2Heart rate variability of LF/HF of CIA rats and control group. Asterisk indicated p < 0.05 when compared with control group
Fig. 3Deceleration and acceleration capacity of CIA rats and control group. The linear regression wasperformed by the least squares method. From the linear regression, the R2 value, the slopes and the y-intercepts are derived. Asterisk indicated p < 0.05 when compared with control group