Literature DB >> 27894001

Multiresolution eXtended Free-Form Deformations (XFFD) for non-rigid registration with discontinuous transforms.

Rui Hua1, Jose M Pozo2, Zeike A Taylor2, Alejandro F Frangi2.   

Abstract

Image registration is an essential technique to obtain point correspondences between anatomical structures from different images. Conventional non-rigid registration methods assume a continuous and smooth deformation field throughout the image. However, the deformation field at the interface of different organs is not necessarily continuous, since the organs may slide over or separate from each other. Therefore, imposing continuity and smoothness ubiquitously would lead to artifacts and increased errors near the discontinuity interface. In computational mechanics, the eXtended Finite Element Method (XFEM) was introduced to handle discontinuities without using computational meshes that conform to the discontinuity geometry. Instead, the interpolation bases themselves were enriched with discontinuous functional terms. Borrowing this concept, we propose a multiresolution eXtented Free-Form Deformation (XFFD) framework that seamlessly integrates within and extends the standard Free-Form Deformation (FFD) approach. Discontinuities are incorporated by enriching the B-spline basis functions coupled with extra degrees of freedom, which are only introduced near the discontinuity interface. In contrast with most previous methods, restricted to sliding motion, no ad hoc penalties or constraints are introduced to reduce gaps and overlaps. This allows XFFD to describe more general discontinuous motions. In addition, we integrate XFFD into a rigorously formulated multiresolution framework by introducing an exact parameter upsampling method. The proposed method has been evaluated in two publicly available datasets: 4D pulmonary CT images from the DIR-Lab dataset and 4D CT liver datasets. The XFFD achieved a Target Registration Error (TRE) of 1.17 ± 0.85 mm in the DIR-lab dataset and 1.94 ± 1.01 mm in the liver dataset, which significantly improves on the performance of the state-of-the-art methods handling discontinuities.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Discontinuity; FFD; Non-rigid registration; Sliding motion

Mesh:

Year:  2016        PMID: 27894001     DOI: 10.1016/j.media.2016.10.008

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  3 in total

1.  Discontinuity Preserving Liver MR Registration with 3D Active Contour Motion Segmentation.

Authors:  Dongxiao Li; Wenxiong Zhong; Kofi M Deh; Thanh Nguyen; Martin R Prince; Yi Wang; Pascal Spincemaille
Journal:  IEEE Trans Biomed Eng       Date:  2018-11-12       Impact factor: 4.538

2.  GIFTed Demons: deformable image registration with local structure-preserving regularization using supervoxels for liver applications.

Authors:  Bartłomiej W Papież; James M Franklin; Mattias P Heinrich; Fergus V Gleeson; Michael Brady; Julia A Schnabel
Journal:  J Med Imaging (Bellingham)       Date:  2018-04-04

3.  Spatiotemporal Free-Form Registration Method Assisted by a Minimum Spanning Tree During Discontinuous Transformations.

Authors:  Jang Pyo Bae; Siyeop Yoon; Malinda Vania; Deukhee Lee
Journal:  J Digit Imaging       Date:  2021-01-22       Impact factor: 4.056

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.