Literature DB >> 27893559

Personalized Reconstruction of Traumatic Orbital Defects Based on Precise Three-Dimensional Orientation and Measurements of the Globe.

Li Huang1, Lisong Lin, Zhihong Wang, Bin Shi, Xiaofeng Zhu, Yu Qiu, Yue Huang, Xueyuan Yu, Yunyang Liao.   

Abstract

OBJECTIVE: The aim of the study was to precisely assess the severity of traumatic orbital defects and techniques for personalized orbital reconstruction.
METHODS: A retrospective study was conducted in 97 patients with traumatic orbital defects who were treated in our hospital between July 2003 and June 2012. Pre- and postoperative spiral computed tomography scans were performed in all patients. A spatial orientation technique was used to measure the three-dimensional position of the globe and calculate the changes in the orbital volume. Subsequently, a computer-assisted technique and a rapid prototyping technique were used to create a personalized orbital model to aid in the planning of surgery as well as the preforming of implants and bone plates. During surgery, the herniated orbital contents were returned; the preformed titanium mesh, Medpor, or other implants were placed; the orbital shape in the defect site was precisely restored; and normal proportions between the orbital walls and orbital contents were regained. The treatment outcomes were evaluated with respect to postoperative appearance, patients' satisfaction, ophthalmologic examination, and computed tomography scan. The complications were analyzed accordingly.
RESULTS: Satisfactory results were achieved in all patients with the following exceptions: 1 patient with an unsatisfactory facial appearance; 2 patients with old trauma and an unfavorable correction of enophthalmos who experienced diplopia with no significant improvement within 6 months after surgery; and 2 patients of mild postoperative lower eyelid ectropion. All other patients achieved satisfactory treatment effects, that is, the orbital shape in the defect site was precisely restored, and normal proportions between the orbital walls and orbital contents were regained. There were no other severe complications reported.
CONCLUSIONS: In patients with traumatic orbital defects, accurate digital evaluations of the three-dimensional position of the globe and changes in the orbital volume aid in surgical planning with a personalized model and promote early surgery with minimal trauma. When the orbital volume was restored and the position of the globe was maintained or corrected, the precise reconstruction of the anatomic shape of the orbit was concurrently completed. Personalized orbital reconstruction can improve the efficacy of plastic surgery in patients with orbital deformities.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 27893559     DOI: 10.1097/SCS.0000000000003201

Source DB:  PubMed          Journal:  J Craniofac Surg        ISSN: 1049-2275            Impact factor:   1.046


  2 in total

1.  Prototyping for the treatment of late zygomatic-orbital fracture: A case report.

Authors:  Amanda Lúcio do Ó Silva; Isabella Jardelino Dias; Rafael Grotta Grempel; Hécio Henrique Araújo de Morais; Nadja Maria da Silva Oliveira Brito; Daliana Queiroga de Castro Gomes
Journal:  Int J Surg Case Rep       Date:  2017-07-11

2.  Quantification of effective orbital volume and its association with axial length of the eye. A 3D-MRI study.

Authors:  Georgios Bontzos; Efrosini Papadaki; Michael Mazonakis; G Thomas Maris; Zoi Kapsala; Styliani Blazaki; E Eleni Drakonaki; T Efstathios Detorakis
Journal:  Rom J Ophthalmol       Date:  2019 Oct-Dec
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.