Literature DB >> 27888094

Nano-analyses of wear particles from metal-on-metal and non-metal-on-metal dual modular neck hip arthroplasty.

Zhidao Xia1, Benjamin F Ricciardi2, Zhao Liu3, Christopher von Ruhland4, Mike Ward5, Alex Lord3, Louise Hughes6, Steven R Goldring7, Edward Purdue7, David Murray8, Giorgio Perino9.   

Abstract

Increased failure rates due to metallic wear particle-associated adverse local tissue reactions (ALTR) is a significant clinical problem in resurfacing and total hip arthroplasty. Retrieved periprosthetic tissue of 53 cases with corrosion/conventional metallic wear particles from 285 revision operations for ALTR was selected for nano-analyses. Three major classes of hip implants associated with ALTR, metal-on-metal hip resurfacing arthroplasty (MoM HRA) and large head total hip replacement (MoM LHTHA) and non-metal-on-metal dual modular neck total hip replacement (Non-MoM DMNTHA) were included. The size, shape, distribution, element composition, and crystal structure of the metal particles were analyzed by conventional histological examination and electron microscopy with analytic tools of 2D X-ray energy dispersive spectrometry and X-ray diffraction. Distinct differences in size, shape, and element composition of the metallic particles were detected in each implant class which correlate with the histological features of severity of ALTR and variability in implant performance.
Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Adverse local tissue reaction (ALTR); Hip arthroplasty; Metal-on-metal hip resurfacing arthroplasty (MoM HRA); Metal-on-metal large head total hip replacement (MoM LHTHA); Non-metal-on-metal dual modular neck total hip replacement (non-MoM DMNTHA)

Mesh:

Substances:

Year:  2016        PMID: 27888094     DOI: 10.1016/j.nano.2016.11.003

Source DB:  PubMed          Journal:  Nanomedicine        ISSN: 1549-9634            Impact factor:   5.307


  19 in total

1.  Fourier transform infrared spectroscopic imaging of wear and corrosion products within joint capsule tissue from total hip replacements patients.

Authors:  Songyun Liu; Deborah J Hall; Stephanie M McCarthy; Joshua J Jacobs; Robert M Urban; Robin Pourzal
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2019-05-17       Impact factor: 3.368

2.  Role of hypoxia inducible factor 1α in cobalt nanoparticle induced cytotoxicity of human THP-1 macrophages.

Authors:  Wendy Rachel Francis; Zhao Liu; Sian E Owens; Xiao Wang; Huaming Xue; Alex Lord; Venkateswarlu Kanamarlapudi; Zhidao Xia
Journal:  Biomater Transl       Date:  2021-06-28

3.  Wear particles induce a new macrophage phenotype with the potential to accelerate material corrosion within total hip replacement interfaces.

Authors:  Divya Rani Bijukumar; Shruti Salunkhe; Guoxing Zheng; Mark Barba; Deborah J Hall; Robin Pourzal; Mathew T Mathew
Journal:  Acta Biomater       Date:  2019-10-31       Impact factor: 8.947

Review 4.  Diagnosis and management of implant debris-associated inflammation.

Authors:  Stuart B Goodman; Jiri Gallo; Emmanuel Gibon; Michiaki Takagi
Journal:  Expert Rev Med Devices       Date:  2019-12-17       Impact factor: 3.166

5.  Analysis of bearing wear, whole blood and synovial fluid metal ion concentrations and histopathological findings in patients with failed ASR hip resurfacings.

Authors:  Lari Lehtovirta; Aleksi Reito; Jyrki Parkkinen; Harry Hothi; Johann Henckel; Alister Hart; Antti Eskelinen
Journal:  BMC Musculoskelet Disord       Date:  2017-12-11       Impact factor: 2.362

6.  Investigation of the effects of electrochemical reactions on complex metal tribocorrosion within the human body.

Authors:  Thomas S Welles; Jeongmin Ahn
Journal:  Heliyon       Date:  2021-05-20

Review 7.  The contribution of the histopathological examination to the diagnosis of adverse local tissue reactions in arthroplasty.

Authors:  Giorgio Perino; Ivan De Martino; Lingxin Zhang; Zhidao Xia; Jiri Gallo; Shonali Natu; David Langton; Monika Huber; Anastasia Rakow; Janosch Schoon; Enrique Gomez-Barrena; Veit Krenn
Journal:  EFORT Open Rev       Date:  2021-06-28

8.  The Chemical Form of Metal Species Released from Corroded Taper Junctions of Hip Implants: Synchrotron Analysis of Patient Tissue.

Authors:  Anna Di Laura; Paul D Quinn; Vasiliki C Panagiotopoulou; Harry S Hothi; Johann Henckel; Jonathan J Powell; Fitim Berisha; Fernanda Amary; J Fred W Mosselmans; John A Skinner; Alister J Hart
Journal:  Sci Rep       Date:  2017-09-08       Impact factor: 4.379

9.  Cobalt (II) ions and nanoparticles induce macrophage retention by ROS-mediated down-regulation of RhoA expression.

Authors:  Jing Xu; Junyao Yang; Agata Nyga; Mazdak Ehteramyan; Ana Moraga; Yuanhao Wu; Lingfang Zeng; Martin M Knight; Julia C Shelton
Journal:  Acta Biomater       Date:  2018-04-09       Impact factor: 8.947

10.  Association between periprosthetic tissue metal content, whole blood and synovial fluid metal ion levels and histopathological findings in patients with failed metal-on-metal hip replacement.

Authors:  Lari Lehtovirta; Aleksi Reito; Jyrki Parkkinen; Sirpa Peräniemi; Jouko Vepsäläinen; Antti Eskelinen
Journal:  PLoS One       Date:  2018-05-16       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.