Literature DB >> 27886597

Paper-based enzymatic electrode with enhanced potentiometric response for monitoring glucose in biological fluids.

Marc Parrilla1, Rocío Cánovas1, Francisco J Andrade2.   

Abstract

A novel paper-based potentiometric sensor with an enhanced response for the detection of glucose in biological fluids is presented. The electrode consists on platinum sputtered on a filter paper and a Nafion membrane to immobilize the enzyme glucose oxidase. The response obtained is proportional to the logarithm of the concentration of glucose, with a sensitivity of -119±8mV·decade-1, a linear range that spans from 10-4M to 10-2.5 M and a limit of detection of 10-4.5 M of glucose. It is shown that Nafion increases the sensitivity of the technique while minimizing interferences. Validation with human serum samples shows an excellent agreement when compared to standard methods. This approach can become an interesting alternative for the development of simple and affordable devices for point of care and home-based diagnostics.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Enzymatic sensors; Glucose; Nafion; Paper-based sensor; Potentiometry

Mesh:

Substances:

Year:  2016        PMID: 27886597     DOI: 10.1016/j.bios.2016.11.034

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

Review 1.  Point-of-care diagnostics for infectious diseases: From methods to devices.

Authors:  Chao Wang; Mei Liu; Zhifei Wang; Song Li; Yan Deng; Nongyue He
Journal:  Nano Today       Date:  2021-02-06       Impact factor: 20.722

Review 2.  Paper and Other Fibrous Materials-A Complete Platform for Biosensing Applications.

Authors:  Domingo R Flores-Hernandez; Vivian J Santamaria-Garcia; Elda M Melchor-Martínez; Juan Eduardo Sosa-Hernández; Roberto Parra-Saldívar; Jaime Bonilla-Rios
Journal:  Biosensors (Basel)       Date:  2021-04-21

3.  Whole virus detection using aptamers and paper-based sensor potentiometry.

Authors:  Subhashish Dolai; Massood Tabib-Azar
Journal:  Med Devices Sens       Date:  2020-09-28

4.  An All-in-One Solid State Thin-Layer Potentiometric Sensor and Biosensor Based on Three-Dimensional Origami Paper Microfluidics.

Authors:  Shiva Pesaran; Elmira Rafatmah; Bahram Hemmateenejad
Journal:  Biosensors (Basel)       Date:  2021-02-10

Review 5.  Unlocking All-Solid Ion Selective Electrodes: Prospects in Crop Detection.

Authors:  Jiawei Zhai; Bin Luo; Aixue Li; Hongtu Dong; Xiaotong Jin; Xiaodong Wang
Journal:  Sensors (Basel)       Date:  2022-07-25       Impact factor: 3.847

6.  A Pencil-Lead Immunosensor for the Rapid Electrochemical Measurement of Anti-Diphtheria Toxin Antibodies.

Authors:  Wilson A Ameku; Vanessa N Ataide; Eric T Costa; Larissa R Gomes; Paloma Napoleão-Pêgo; David William Provance; Thiago R L C Paixão; Maiara O Salles; Salvatore Giovanni De-Simone
Journal:  Biosensors (Basel)       Date:  2021-11-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.