Literature DB >> 27886563

Nanomechanical properties, wear resistance and in-vitro characterization of Ta2O5 nanotubes coating on biomedical grade Ti-6Al-4V.

Masoud Sarraf1, Bushroa Abdul Razak2, Bahman Nasiri-Tabrizi3, Ali Dabbagh4, Noor Hayaty Abu Kasim5, Wan Jefrey Basirun6, Eshamsul Bin Sulaiman5.   

Abstract

Tantalum pentoxide nanotubes (Ta2O5 NTs) can dramatically raise the biological functions of different kinds of cells, thus have promising applications in biomedical fields. In this study, Ta2O5 NTs were prepared on biomedical grade Ti-6Al-4V alloy (Ti64) via physical vapor deposition (PVD) and a successive two-step anodization in H2SO4: HF (99:1)+5% EG electrolyte at a constant potential of 15V. To improve the adhesion of nanotubular array coating on Ti64, heat treatment was carried out at 450°C for 1h under atmospheric pressure with a heating/cooling rate of 1°Cmin-1. The surface topography and composition of the nanostructured coatings were examined by atomic force microscopy (AFM) and X-ray electron spectroscopy (XPS), to gather information about the corrosion behavior, wear resistance and bioactivity in simulated body fluids (SBF). From the nanoindentation experiments, the Young's modulus and hardness of the 5min anodized sample were ~ 135 and 6GPa, but increased to ~ 160 and 7.5GPa, respectively, after annealing at 450°C. It was shown that the corrosion resistance of Ti64 plates with nanotubular surface modification was higher than that of the bare substrate, where the 450°C annealed specimen revealed the highest corrosion protection efficiency (99%). Results from the SBF tests showed that a bone-like apatite layer was formed on nanotubular array coating, as early as the first day of immersion in simulated body fluid (SBF), indicating the importance of nanotubular configuration on the in-vitro bioactivity.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Corrosion resistance; In-vitro bioactivity; Mechanical properties; Ta(2)O(5) nanotubes; Ti–6Al–4V

Mesh:

Substances:

Year:  2016        PMID: 27886563     DOI: 10.1016/j.jmbbm.2016.11.012

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  12 in total

Review 1.  Mixed oxide nanotubes in nanomedicine: A dead-end or a bridge to the future?

Authors:  Masoud Sarraf; Bahman Nasiri-Tabrizi; Chai Hong Yeong; Hamid Reza Madaah Hosseini; Saeed Saber-Samandari; Wan Jefrey Basirun; Takuya Tsuzuki
Journal:  Ceram Int       Date:  2020-09-24       Impact factor: 4.527

2.  Effect of CeO₂ on Microstructure and Wear Resistance of TiC Bioinert Coatings on Ti6Al4V Alloy by Laser Cladding.

Authors:  Tao Chen; Defu Liu; Fan Wu; Haojun Wang
Journal:  Materials (Basel)       Date:  2017-12-31       Impact factor: 3.623

Review 3.  Surface Modification Techniques of Titanium and its Alloys to Functionally Optimize Their Biomedical Properties: Thematic Review.

Authors:  Tong Xue; Shokouh Attarilar; Shifeng Liu; Jia Liu; Xi Song; Lanjie Li; Beibei Zhao; Yujin Tang
Journal:  Front Bioeng Biotechnol       Date:  2020-11-11

4.  Microstructural, Tribology and Corrosion Properties of Optimized Fe3O4-SiC Reinforced Aluminum Matrix Hybrid Nano Filler Composite Fabricated through Powder Metallurgy Method.

Authors:  Negin Ashrafi; M A Azmah Hanim; Masoud Sarraf; S Sulaiman; T S Hong
Journal:  Materials (Basel)       Date:  2020-09-15       Impact factor: 3.623

5.  Nanostructured Coating of Non-Crystalline Tantalum Pentoxide on Polyetheretherketone Enhances RBMS Cells/HGE Cells Adhesion.

Authors:  Zhiying Pang; Zhangyi Pan; Min Ma; Zhiyan Xu; Shiqi Mei; Zengxin Jiang; Feng Yin
Journal:  Int J Nanomedicine       Date:  2021-01-29

Review 6.  A state-of-the-art review of the fabrication and characteristics of titanium and its alloys for biomedical applications.

Authors:  Masoud Sarraf; Erfan Rezvani Ghomi; Saeid Alipour; Seeram Ramakrishna; Nazatul Liana Sukiman
Journal:  Biodes Manuf       Date:  2021-10-26

7.  Micro/Nano Structural Tantalum Coating for Enhanced Osteogenic Differentiation of Human Bone Marrow Stem Cells.

Authors:  Ding Ding; Youtao Xie; Kai Li; Liping Huang; Xuebin Zheng
Journal:  Materials (Basel)       Date:  2018-04-03       Impact factor: 3.623

8.  Fabrication of Durable Ordered Ta2O5 Nanotube Arrays Decorated with Bi2S3 Quantum Dots.

Authors:  Mateusz A Baluk; Marek P Kobylański; Wojciech Lisowski; Grzegorz Trykowski; Tomasz Klimczuk; Paweł Mazierski; Adriana Zaleska-Medynska
Journal:  Nanomaterials (Basel)       Date:  2019-09-20       Impact factor: 5.076

9.  Titania Nanofiber Scaffolds with Enhanced Biointegration Activity-Preliminary In Vitro Studies.

Authors:  Michalina Ehlert; Katarzyna Roszek; Tomasz Jędrzejewski; Michał Bartmański; Aleksandra Radtke
Journal:  Int J Mol Sci       Date:  2019-11-11       Impact factor: 5.923

10.  Enhancing Corrosion and Wear Resistance of Ti6Al4V Alloy Using CNTs Mixed Electro-Discharge Process.

Authors:  Gurpreet Singh; Timur Rizovich Ablyaz; Evgeny Sergeevich Shlykov; Karim Ravilevich Muratov; Amandeep Singh Bhui; Sarabjeet Singh Sidhu
Journal:  Micromachines (Basel)       Date:  2020-09-12       Impact factor: 2.891

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.