Kyung Ho Kim1, Samuel Lara-Avila2, Hojin Kang1, Hans He2, Johnas Eklӧf3, Sung Ju Hong1, Min Park1, Kasper Moth-Poulsen3, Satoshi Matsushita4, Kazuo Akagi4, Sergey Kubatkin2, Yung Woo Park1.
Abstract
We induce dramatic changes in the structure of conducEntities:
Year: 2016 PMID: 27886233 PMCID: PMC5122886 DOI: 10.1038/srep37783
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1Structural differences between pristine and carbonized polymers and I-V characteristics of CPA and CPANI nanofibers.
(a) Possible cross-linking of PA (adapted from ref. 30) and PANI (adapted from refs 33 and 34) after carbonization at 800 °C. (b) Raman spectra of PA and PANI nanofibers show characteristic peaks of trans-PA at 1475 and 1085 cm−1 and complex peaks of HCl doped PANI at 1620, 1590, 1505, 1405, 1340, 1260, and 1170 cm−1. After carbonization, broad graphite G and disordered D bands were observed in both CPA and CPANI nanofibers. Data for PA and PANI are normalized with respect to the intensity of D band and shifted for clarity. (c,d) I-V (E-J) characteristics of CPA (c) and CPANI (d) nanofibers. Inset figures are scanning electron microscope (SEM) images of CPA (c) and CPANI (d) nanofibers with Ti/Au top contact electrodes.
Figure 2ES-VRH behaviors of CPA and CPANI nanofibers.
(a) The temperature dependence of the Ohmic conductance at low bias voltages follows the ES-VRH, G(T) ∝ exp[−(T0/T)]1/2 at T < 180 K and deviates from the ES-VRH at T > 180 K. (b) The bias electric field dependence of the non-Ohmic conductance at low temperatures (T < 10 K) and high voltages (V > ~ 1 V) shows the characteristic of the ES-VRH, G(E) ∝ exp[−(E0/E)]1/2.
Figure 3Universal scaling of CPA and CPANI nanofibers.
I/T1+ vs eV/kT plot of both CPA (a) and CPANI (b) nanofibers. Inset shows power law dependence of Ohmic conductance, G(T) ∝ T in both CPA (a) and CPANI (b) nanofibers. Fit to Eq. 1 (black curves) gives fitting parameters I0, β, and γ.
Fitting parameters for pristine and carbonized polymer nanofibers.
| PA | 5.47 | 6.88 | 4.9 × 10−23 | 40 |
| CPA | 4.14 | 5.28 | 3.0 × 10−21 | 100 |
| PANI | 5.34 | 6.28 | 8.3 × 10−23 | 303 |
| CPANI | 2.93 | 4.25 | 1.0 × 10−15 | 205 |
Figure 4Comparison of universal scaling between pristine and carbonized polymer nanofibers.
Normalized power law scaling I/I0T vs γeV/kT of both pristine and carbonized polymer nanofibers shows similar transport in these systems. Crossovers of slopes in all scaled curves occur when γeV/kT ~ 1.