Literature DB >> 27886000

Evaluation of corrosion resistance and surface characteristics of orthodontic wires immersed in different mouthwashes.

Didem Nalbantgil1, Feyza Ulkur1, Gulfeza Kardas2, Mustafa Culha3.   

Abstract

BACKGROUND: Patients use mouthwashes in addition to mechanical cleaning during orthodontic treatment. The effects of mouthwashes on the archwires have not been examined yet.
OBJECTIVE: To compare the corrosion resistance of four different arch wires and corrosion effects of different mouthwashes to formulate a biocompatible and mechanically useful arch wire and mouthwash combination.
METHODS: Each group comprised of 4 wire samples of 2 cm 0.016 × 0.022 inch. 1st group: ion implanted nickel titanium (INT), 2nd group: nickel titanium, without ion implantation (NT), 3rd group: micro layered esthetic nickel titanium (ENT), 4th group: stainless steel (SS) wires. They were immersed inside 2 ml of artificial saliva solutions (AS) for the control, or AS (9%) combined with 1 of the 3 mouthwashes (91%) for study groups, for 24 hours. These mouthwashes were essential oil (EO), chlorhexidine (CHX), sodium-fluoride (NaF). An electrochemical analyzer was used for electrochemical impedance spectroscopy measurements.
RESULTS: High corrosion resistance was obtained for ENT than the other wires. The corrosion potentials are 0.007, -0.042, 0.074 and -0.015 V (Ag/AgCl) for ENT, INT, SS and NT in the artificial salivary, respectively. In NaF containing mouthwash Rp value of ENT is significantly high in comparison to others. The impedance responses of all materials increased significantly in the presence of NaF mouthwash as well as in the CHX mouthwash. Low frequencies are seen at all materials in EO mouthwash. Diameters of loops are 22, 5.9, 5.9 and 3.7 MΩ at ENT, INT, SS and NT.
CONCLUSIONS: In this study, micro layered esthetic nickel titanium wires are found biocompatible among other wires and NaF and CHX mouthwashes can be recommend for their good corrosion resistance during fixed orthodontic therapy.

Entities:  

Keywords:  Corrosion resistance; mouthwashes; orthodontic wires

Mesh:

Substances:

Year:  2016        PMID: 27886000     DOI: 10.3233/BME-161607

Source DB:  PubMed          Journal:  Biomed Mater Eng        ISSN: 0959-2989            Impact factor:   1.300


  3 in total

1.  Effect of 0.05% Sodium Fluoride Mouthwash on Surface Roughness and Friction between Ceramic Brackets and Rhodium-Coated and Uncoated Stainless Steel Wires.

Authors:  Tahereh Hosseinzadeh Nik; Hannaneh Ghadirian; Tabassom Hooshmand; Mohammad Javad Kharazifard; Maryam Nasiri; Maryam Javaheri Mahd
Journal:  Front Dent       Date:  2019-04-30

2.  Surface Evaluation of Orthodontic Brackets Using Texture and Fractal Dimension Analysis.

Authors:  Michał Sarul; Marcin Mikulewicz; Marcin Kozakiewicz; Kamil Jurczyszyn
Journal:  Materials (Basel)       Date:  2022-03-11       Impact factor: 3.623

3.  Surface characterization and frictional force between stainless steel brackets and archwires in orthodontic patients using chlorhexidine- and Persica-containing mouthrinses: A randomized controlled trial.

Authors:  Elham-Sadat Emadian Razavi; Tahereh Hosseinzadeh Nik; Tabassom Hooshmand; Habibeh Farazdaghi; Arian Hesam Arefi
Journal:  Dent Res J (Isfahan)       Date:  2021-04-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.