Literature DB >> 27884628

Skirt followed by trouser stenting technique: True anatomical preservation of coronary Y-shaped bifurcation lesions while using "vanishing" bioresorbable scaffolds: A report of two cases.

Wael Elabbassi1, Arif Al Nooryani2.   

Abstract

We report on two cases in which Y-shaped coronary bifurcations were treated with the use of Bioresorbable scaffolds. The first case was of a 50-year-old man with NSTEMI. Coronary angiography showed stenosis involving a Y-shaped bifurcation of proximal to mid LAD and diagonal. The lesion was wired using two 0.14 BMW guide wires, followed by serial pre-dilatation of LAD and Diagonal branch. The stent into proximal LAD was deployed first as a skirt (3.5 × 12 BVS). Stent was post-dilated. A second 2.5 × 28 BVS was deployed into diagonal branch, protruding backwards; along with a 2.0 × 15 SC balloon continuing into the mid LAD. Both balloons where pulled back proximally and re-inflated. The technique was repeated in reversed order for stenting the mid LAD using the third BVS (3.0 × 18 BVS). Finally two NC balloons where used to post-dilate both legs of the newly-formed trouser. The result was checked by OCT. The second case was that of a 62-year-old man with chest pain and NSTEMI. He had a history of previous PCI to LCx using bare metal stent. Coronary angiogram showed severe in-stent restenosis in mid LCX, extending into two large obtuse marginal branches. After wiring both OMs, serial pre-dilatation was done with two NC 2.5 × 20 balloons, followed by initial stenting of mid LCx inside old stent, as the proximal segment of bifurcation, using a 3.5 × 12 BVS, followed by implanting a 2.5 × 28 BVS into OM2 and 2.5 × 18 into OM1. At 6 months a clinical follow up via telephone contact revealed no recurrence of chest pain in both cases and no further intervention required.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Bifurcation stenting; Bioresorbable scaffolds; Percutaneous intervention

Mesh:

Year:  2016        PMID: 27884628     DOI: 10.1016/j.carrev.2016.10.007

Source DB:  PubMed          Journal:  Cardiovasc Revasc Med        ISSN: 1878-0938


  1 in total

1.  Customizable Angioplasty Balloon-Forming Machine: Towards Precision Medicine in Coronary Bifurcation Lesion Interventions.

Authors:  Kaitlyn M Elmer; Maxwell J Bean; Barry F Uretsky; Sam E Stephens; Hanna K Jensen; Morten O Jensen
Journal:  J Cardiovasc Transl Res       Date:  2022-03-21       Impact factor: 4.132

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.