Literature DB >> 27874943

MR-enterography with diffusion weighted imaging: ADC values in normal and pathological bowel loops, a possible threshold ADC value to differentiate active from inactive Crohn's disease.

V Ninivaggi1, M Missere, G Restaino, E Gangemi, M Di Matteo, A Pierro, G Sallustio, L Bonomo.   

Abstract

OBJECTIVE: The aim of our study was to compare the apparent diffusion coefficient (ADC) values of pathological bowel loops wall (pADC) with the ADC values of normal appearing ones (naADC) and to determine a discriminating threshold. PATIENTS AND METHODS: 60 patients were studied at our Institution through a MR-enterography that included free-breathing axial Diffusion Weighted Imaging (DWI) with two b (0 and 800 s/mm2) after histological diagnosis of active Crohn's disease (CD). The one (when unique) or the best analyzable (when multiple) pathological bowel loop was identified in each patient, on the basis of the MRI features: wall thickness, presence of mural oedema and wall contrast enhancement after contrast medium administration. A normal appearing bowel loop was used for comparison. ADC values were measured in consensus by two radiologists, and they were compared with t-test. The ADC threshold value for the differentiation between pathological and normal appearing bowel loops was determined.
RESULTS: The pADC values were significantly lower than the naADC values (1.48 ± 0.058 x 10-3 mm2/s versus 3.525 ± 0.07 x 10-3 mm2/s; p < 0.05). A threshold of 2.416 x 10-3 mm2/s showed 100% sensitivity and 100% specificity for the discrimination between normal and pathological bowel loops.
CONCLUSIONS: In patients with active CD the ADC values of the pathological bowel wall are significantly lower than those of normal appearing bowel loops. A threshold of ADC value of 2.416 10-3 mm2/s could discriminate normal from pathological bowel loops.

Entities:  

Mesh:

Year:  2016        PMID: 27874943

Source DB:  PubMed          Journal:  Eur Rev Med Pharmacol Sci        ISSN: 1128-3602            Impact factor:   3.507


  4 in total

1.  Apparent diffusion coefficient for assessing Crohn's disease activity: a meta-analysis.

Authors:  Maximilian Thormann; Bohdan Melekh; Caroline Bär; Maciej Pech; Jazan Omari; Andreas Wienke; Hans-Jonas Meyer; Alexey Surov
Journal:  Eur Radiol       Date:  2022-09-28       Impact factor: 7.034

2.  Mesenteric lymph nodes in MR enterography: are they reliable followers of bowel in active Crohn's disease?

Authors:  Amir Reza Radmard; Rana Eftekhar Vaghefi; Seyed Ali Montazeri; Sara Naybandi Atashi; Amir Pejman Hashemi Taheri; Sepehr Haghighi; Aneseh Salehnia; Mehrdad Dadgostar; Reza Malekzadeh
Journal:  Eur Radiol       Date:  2018-04-25       Impact factor: 5.315

Review 3.  A review of magnetic resonance enterography-based indices for quantification of Crohn's disease inflammation.

Authors:  Noa Rozendorn; Marianne Michal Amitai; Rami Abraham Eliakim; Uri Kopylov; Eyal Klang
Journal:  Therap Adv Gastroenterol       Date:  2018-04-13       Impact factor: 4.409

4.  Can MR Enterography and Diffusion-Weighted Imaging Predict Disease Activity Assessed by Simple Endoscopic Score for Crohn's Disease?

Authors:  Levent Soydan; Ali Aslan Demir; Serhat Ozer; Selvinaz Ozkara
Journal:  J Belg Soc Radiol       Date:  2019-01-18       Impact factor: 1.894

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.