| Literature DB >> 27873820 |
Yi-Hung Liao1,2, Jung-Chuan Chou3,4.
Abstract
The drug sensing properties of procaine and berberine drug sensors based on ruthenium dioxide thin film were investigated. Ruthenium dioxide (RuO₂) membrane prepared using a sputtering method was used as substrates for the drug sensors. The procaine and berberine drug sensors were prepared using a drug-sensitive membrane that measured the procaine and berberine concentration in a linear range from 1×10-2 M to 1×10-6 M and from 1×10-2 M to 1×10-7 M, respectively. The drift rates and hyteresis widths of these ruthenium dioxide based drug sensors were also investigated.Entities:
Keywords: Procaine drug sensor; berberine drug sensor; drift rate; hysteresis width; ruthenium dioxide
Year: 2008 PMID: 27873820 PMCID: PMC3705510 DOI: 10.3390/s8095386
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1.(a) Cross section of ruthenium dioxide membrane. (b) Cross section of procaine and berberine drug sensors.
Figure 2.Voltage-time measurement system used for drug sensors
Figure 3.Response voltage versus time characteristics and sensitivity of ruthenium dioxide based procaine drug sensor from 10-2 M to 10-6 M concentrations
Figure 4.Response voltage versus time characteristics and sensitivity of ruthenium dioxide based berberine drug sensor from 10-2 M to 10-7 M concentrations.
Comparison of linear detection range and detection limit of procaine and berberine drug sensors.
| Procaine | |||
|---|---|---|---|
|
| |||
| substrate | Linear detection range | Detection limit | Ref. |
|
| |||
| RuO2/Si | 1×10-6 M-1×10-2 M | 2×10-7 M | In this study |
| MWNT/GCE | 5×10-7 M-1×10-4 M | 2×10-7 M | [ |
| Carbon electrode | 9×10-6 M-1×10-4 M | 6×10-6 M | [ |
| Indium tin oxide | 1×10-6 M-1×10-2 M | - | [ |
| Piezoelectric quartz crystal | 8.3×10-8 M-5.0×10-3 M | 8.3×10-8 M | [ |
| Berberine | |||
|
| |||
| substrate | Linear detection range | Detection limit | Ref. |
|
| |||
| RuO2/Si | 1×10-7 M - 1×10-2 M | 2×10-8 M | In this study |
| Quartz plate | 4×10-7 M - 2×10-5 M | 8×10-8 M | [ |
| Quartz plate | 7.5×10-7 M - 5.6×10-4 M | - | [ |
| Quartz plate | 7×10-1 M - 4×10-9 M | 3×10-11 M | [ |
| Conjugated polymer | 7.5×10-7 M - 7.5×10-4 M | - | [ |
| Copolymer | 4.02×10-7 M - 2.82×10-4 M | - | [ |
| SnO2/ITO | 5×10-7 M - 1×10-3 M | - | [ |
Figure 5.Drift rates of procaine and berberine drug sensors based on ruthenium dioxide membrane in 10-2 M concentration measurement between 5 and 12 hours.