Literature DB >> 27865561

The cost effectiveness of vacuum-assisted versus core-needle versus surgical biopsy of breast lesions.

P Fernández-García1, S F Marco-Doménech2, L Lizán-Tudela3, M V Ibáñez-Gual4, A Navarro-Ballester5, E Casanovas-Feliu5.   

Abstract

OBJECTIVES: To determine the cost effectiveness of breast biopsy by 9G vacuum-assisted guided by vertical stereotaxy or ultrasonography in comparison with breast biopsy by 14G core-needle biopsy and surgical biopsy.
MATERIAL AND METHODS: We analyzed a total of 997 biopsies (181 vacuum-assisted, 626 core, and 190 surgical biopsies). We calculated the total costs (indirect and direct) of the three types of biopsy. We did not calculate intangible costs. We measured the percentage of correct diagnoses obtained with each technique. To identify the most cost-effective option, we calculated the mean ratios for the three types of biopsies.
RESULTS: Total costs were €225.09 for core biopsy, €638.90 for vacuum-assisted biopsy, and €1780.01 for surgical biopsy. The overall percentage of correct diagnoses was 91.81% for core biopsy, 94.03% for vacuum-assisted biopsy, and 100% for surgical biopsy; however, these differences did not reach statistical significance (p=0.3485). For microcalcifications, the percentage of correct diagnoses was 50% for core biopsy and 96.77% for vacuum-assisted biopsy (p<0.0001). For nodules, there were no significant differences among techniques. The mean cost-effectiveness ratio considering all lesions was 2.45 for core biopsy, 6.79 for vacuum-assisted biopsy, and 17.80 for surgical biopsy.
CONCLUSION: Core biopsy was the dominant option for the diagnosis of suspicious breast lesions in general. However, in cases with microcalcifications, the low percentage of correct diagnoses achieved by core biopsy (50%) advises against its use in this context, where vacuum-assisted biopsy would be the technique of choice because it is more cost-effective than surgical biopsy, the other technique indicated for biopsying microcalcifications.
Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

Entities:  

Keywords:  Biopsia mamaria asistida por vacío; Biopsia mamaria con aguja gruesa; Biopsia mamaria quirúrgica; Core-needle breast biopsy; Cost effectiveness; Costo-efectividad; Surgical breast biopsy; Vacuum-assisted breast biopsy

Mesh:

Year:  2016        PMID: 27865561     DOI: 10.1016/j.rx.2016.09.006

Source DB:  PubMed          Journal:  Radiologia        ISSN: 0033-8338


  2 in total

1.  A comparison of diagnostic performance of vacuum-assisted biopsy and core needle biopsy for breast microcalcification: a systematic review and meta-analysis.

Authors:  Xu Chen Huang; Xu Hua Hu; Xiao Ran Wang; Chao Xi Zhou; Fei Fei Wang; Shan Yang; Gui Ying Wang
Journal:  Ir J Med Sci       Date:  2018-03-16       Impact factor: 1.568

Review 2.  Efficacy and safety of microwave ablation for benign breast lesions: a systematic review and meta-analysis.

Authors:  Chuchu Xu; Qinghong Yu; Mengqian Wang; Jiayan Zhu; Zimei Yang; Shan Liu; Xiufei Gao
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2022-04-20       Impact factor: 1.627

  2 in total