Literature DB >> 27864456

Endovascular Treatment of Common Iliac Artery Aneurysms With an Iliac Branch Device: Multicenter Experience of 140 Patients.

Hidde Jongsma1, Joost A Bekken1, Wouter J J Bekkers1, Clark J Zeebregts2, Joost van Herwaarden3, Arjan Hoksbergen4, Philip Cuypers5, Jean Paul P M de Vries6, Hence J Verhagen7, Bram Fioole1.   

Abstract

PURPOSE: To evaluate the efficacy, feasibility, and long-term outcomes of the Zenith ZBIS iliac branch device (IBD) to preserve internal iliac artery (IIA) perfusion in a large Dutch multicenter cohort.
METHODS: Between September 2004 and August 2015, 140 patients (mean age 70.9±7.4 years; 130 men) with 162 IBD implantations were identified in 7 vascular centers. The indication for IBD implantation was an abdominal aortic aneurysm >55 mm with a concomitant common iliac artery (CIA) aneurysm >20 mm (n=40), a CIA aneurysm with a diameter >30 mm (n=89), or revision of a type Ib endoleak after endovascular aneurysm repair (n=11).
RESULTS: Technical success (aneurysm exclusion, no type I or III endoleak, and a patent IIA) was obtained in 157 (96.9%) of 162 IBD implantations. Six (4.3%) patients developed major complications; 2 (1.4%) died. Mean follow-up was 26.6±24.1 months, during which 17 (12.1%) IBD-associated secondary interventions were performed. Including technical failures and intentional IIA embolizations, 15 (9.3%) IIA branch occlusions were identified; buttock claudication developed in 6 of these patients. The freedom from secondary intervention estimate was 75.9% (95% confidence interval 59.7 to 86.3) at 5 years.
CONCLUSION: CIA aneurysms can be treated safely and effectively by IBDs with preservation of antegrade flow to the IIA. Secondary interventions are indicated in >10% of patients during follow-up but can be performed endovascularly in most.

Entities:  

Keywords:  abdominal aortic aneurysm; branch occlusion; branched stent-graft; common iliac artery aneurysm; complications; endoleak; endovascular aneurysm repair; hypogastric artery; iliac artery; internal iliac artery; mortality; reintervention

Mesh:

Year:  2016        PMID: 27864456     DOI: 10.1177/1526602816679132

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  3 in total

Review 1.  Endovascular Treatment of Various Aortic Pathologies: Review of the Latest Data and Technologies.

Authors:  Koji Maeda; Takao Ohki; Yuji Kanaoka
Journal:  Int J Angiol       Date:  2018-05-07

2.  Midterm result of custom-made iliac branch device for common iliac aneurysm with and without abdominal aortic aneurysm.

Authors:  Chun-Yang Huang; Po-Lin Chen; Hsin-Ying Lu; Hung-Lung Hsu; Tzu-Ting Kuo; I-Ming Chen; Chiao-Po Hsu; Chun-Che Shih
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-01-01

3.  In-vitro and In-silico Haemodynamic Analyses of a Novel Embedded Iliac Branch Device.

Authors:  Shichao Liang; Heyue Jia; Xuehuan Zhang; Wei Guo; Guojing Zhou; Shilong Li; Panpan Yuan; Jiang Xiong; Duanduan Chen
Journal:  Front Cardiovasc Med       Date:  2022-04-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.