Literature DB >> 27862034

Homogeneity of echo intensity values in transverse ultrasound images.

Alyssa N Varanoske1, David H Fukuda1, Carleigh H Boone1, Kyle S Beyer1, Jeffrey R Stout1, Jay R Hoffman1.   

Abstract

INTRODUCTION: Echo intensity of skeletal muscle measured by means of ultrasonography has been used to assess muscle quality, however, the heterogeneity of echo intensity has not been thoroughly investigated. Therefore, this study examined echo intensity in different sections of panoramic ultrasound images captured in the transverse plane.
METHODS: Echo intensity of the vastus lateralis was assessed in 24 men (20.2 ± 1.6 years) using panoramic ultrasonography. Echo intensity homogeneity was examined by dividing each image into 3 compartments of equal horizontal length (tertiles).
RESULTS: No differences were found between echo intensity of the anterior tertile (59.1 ± 9.1 AU), posterior tertile (56.4 ± 9.9 AU), lateral tertile (58.7 ± 9.9 AU), or the overall panoramic image (58.0 ± 8.8 AU).
CONCLUSIONS: Echo intensity of the vastus lateralis appears to be homogeneous as assessed in the transverse plane. Further research is necessary to determine if still imaging is sufficient to obtain an accurate measure of echo intensity. Muscle Nerve 56: 93-98, 2017.
© 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  compartments; echo intensity; echogenicity; homogeneity; panoramic; ultrasonography

Mesh:

Year:  2017        PMID: 27862034     DOI: 10.1002/mus.25470

Source DB:  PubMed          Journal:  Muscle Nerve        ISSN: 0148-639X            Impact factor:   3.217


  3 in total

1.  Influence of subcutaneous adipose thickness and dominance on reliability of quadriceps muscle quality in healthy young individuals.

Authors:  Jaquelini Betta Canever; Fábio Juner Lanferdini; Bruno Monteiro de Moura; Fernando Diefenthaeler; Kelly Mônica Marinho E Lima
Journal:  J Ultrasound       Date:  2021-09-14

2.  Short-term neuromuscular, morphological, and architectural responses to eccentric quasi-isometric muscle actions.

Authors:  Dustin J Oranchuk; André R Nelson; Adam G Storey; Shelley N Diewald; John B Cronin
Journal:  Eur J Appl Physiol       Date:  2020-09-29       Impact factor: 3.078

3.  Test-retest reliability of nerve and muscle morphometric characteristics utilizing ultrasound imaging in individuals with unilateral sciatica and controls.

Authors:  Hadi Sarafraz; Mohammad Reza Hadian; Niloofar Ayoobi Yazdi; Gholamreza Olyaei; Hossein Bagheri; Shohreh Jalaie; Omid Rasouli
Journal:  Chiropr Man Therap       Date:  2018-11-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.