Literature DB >> 27861650

Influence of Four Different Abutment Materials and the Adhesive Joint of Two-Piece Abutments on Cervical Implant Bone and Soft Tissue.

Christian Mehl, Volker Gassling, Stephan Schultz-Langerhans, Yahya Açil, Telse Bähr, Jörg Wiltfang, Matthias Kern.   

Abstract

PURPOSE: The main aim of this study was to evaluate the influence of four different abutment materials and the adhesive joint of two-piece abutments on the cervical implant bone and soft tissue.
MATERIALS AND METHODS: Sixty-four titanium implants (Camlog Conelog; 4.3 ± 9 mm) were placed bone level into the edentulous arches of four minipigs. Four different types of abutments were placed at implant exposure: zirconium dioxide, lithium disilicate, and titanium bonded to a titanium luting base with resin cement; one-piece titanium abutments served as the control. The animals were sacrificed 6 months after implant exposure, and the bone-to-implant contact (BIC) area, sulcus depth, the length of the junctional epithelium and the connective tissue, the biologic width, and first cervical BIC-implant shoulder distance were measured using histomorphometry and light and fluorescence microscopy.
RESULTS: Overall, 14 implants were lost (22%). At exposure, the implant shoulder-bone distance was 0.6 ± 0.7 mm. Six months later, the bone loss was 2.1 ± 1.2 mm measured histomorphometrically. There was a significant difference between the two measurements (P ≤ .0001). No significant influence could be found between any of the abutment materials with regard to bone loss or soft tissue anatomy (P > .05), with the exception of zirconium dioxide and onepiece titanium abutments when measuring the length of the junctional epithelium (P ≤ .01). The maxilla provided significantly more soft tissue and less bone loss compared with the mandible (P ≤ .02).
CONCLUSION: All tested abutment materials and techniques seem to be comparable with regard to soft tissue properties and the cervical bone level.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27861650     DOI: 10.11607/jomi.5321

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  6 in total

1.  Application of a standard autoclaving protocol does not harm structural integrity of two-piece zirconia abutments under detachment force testing.

Authors:  Dieter Pils; Ralf J Baeppler; Rüdiger Junker; Andrej M Kielbassa; Frank P Nothdurft
Journal:  Clin Oral Investig       Date:  2019-05-10       Impact factor: 3.573

2.  Effect Morphology and Surface Treatment of the Abutments of Dental Implants on the Dimension and Health of Peri-Implant Biological Space.

Authors:  Ibrahim Dib-Zaitum; Yasmina Guadilla-González; Javier Flores-Fraile; Juan Dib-Zakkour; Lorena Benito-Garzón; Javier Montero
Journal:  Materials (Basel)       Date:  2022-06-22       Impact factor: 3.748

3.  Survival Probability, Weibull Characteristics, Stress Distribution, and Fractographic Analysis of Polymer-Infiltrated Ceramic Network Restorations Cemented on a Chairside Titanium Base: An In Vitro and In Silico Study.

Authors:  João P M Tribst; Amanda M O Dal Piva; Alexandre L S Borges; Lilian C Anami; Cornelis J Kleverlaan; Marco A Bottino
Journal:  Materials (Basel)       Date:  2020-04-16       Impact factor: 3.623

Review 4.  Biological Responses to the Transitional Area of Dental Implants: Material- and Structure-Dependent Responses of Peri-Implant Tissue to Abutments.

Authors:  Jung-Ju Kim; Jae-Hyun Lee; Jeong Chan Kim; Jun-Beom Lee; In-Sung Luke Yeo
Journal:  Materials (Basel)       Date:  2019-12-22       Impact factor: 3.623

5.  Prosthodontics Using Removable Platform Switching Technologies (Multiunit, On1) as Exemplified by Conical Connection Implant Systems for Early and Immediate Loading.

Authors:  Roman Studenikin
Journal:  Int J Dent       Date:  2021-04-19

6.  The minipig intraoral dental implant model: A systematic review and meta-analysis.

Authors:  Marta Liliana Musskopf; Amanda Finger Stadler; Ulf Me Wikesjö; Cristiano Susin
Journal:  PLoS One       Date:  2022-02-28       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.