Literature DB >> 27860327

Parallel online multi-wavelength (2D) fluorescence spectroscopy in each well of a continuously shaken microtiter plate.

Tobias Ladner1, Mario Beckers1, Bernd Hitzmann2, Jochen Büchs1.   

Abstract

Small-scale high-throughput screening devices are becoming increasingly important in bioprocess development. Conventional dipping probes for process monitoring are often too large to be used in these devices. Thus, optical measurements are often the method of choice. Even some parameters that cannot directly be measured by fluorescence become accessible via sensitive fluorescence dyes. However, not all compounds of interest are measurable by this technique. Recent studies applying multi-wavelength (2D) fluorescence spectroscopy in combination with chemometrics have shown that information on numerous analytes is obscured by the fluorescence data. Hitherto, this measurement technique has only been available on the scale of stirred tank fermenters. This work introduces a new device for multi-wavelength (2D) fluorescence spectroscopy in each well of a continuously shaken microtiter plate. Using a combination of spectrograph and CCD detector, the required time per measurement cycle in a 48-well microtiter plate was 0.5 h. Cultures of Hansenula polymorpha and Escherichia coli are monitored. The concentrations of glycerol, glucose and acetate as well as pH are determined using partial least square (PLS) models. Because a pH-sensitive fluorescence dye was not required, no dependency of the pKa of a fluorescence dye exists, and measurements in the low pH range can be obtained.
Copyright © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  (2D) Fluorescence spectroscopy; Chemometrics; High-throughput system; Microtiter plate; Multi-wavelength; Online monitoring

Mesh:

Substances:

Year:  2016        PMID: 27860327     DOI: 10.1002/biot.201600515

Source DB:  PubMed          Journal:  Biotechnol J        ISSN: 1860-6768            Impact factor:   4.677


  4 in total

1.  Prediction of Escherichia coli expression performance in microtiter plates by analyzing only the temporal development of scattered light during culture.

Authors:  Tobias Ladner; Martina Mühlmann; Andreas Schulte; Georg Wandrey; Jochen Büchs
Journal:  J Biol Eng       Date:  2017-07-03       Impact factor: 4.355

Review 2.  Measurement Techniques to Resolve and Control Population Dynamics of Mixed-Culture Processes.

Authors:  Ivan Schlembach; Alexander Grünberger; Miriam A Rosenbaum; Lars Regestein
Journal:  Trends Biotechnol       Date:  2021-02-08       Impact factor: 21.942

3.  Online 2D Fluorescence Monitoring in Microtiter Plates Allows Prediction of Cultivation Parameters and Considerable Reduction in Sampling Efforts for Parallel Cultivations of Hansenula polymorpha.

Authors:  Christoph Berg; Nina Ihling; Maurice Finger; Olivier Paquet-Durand; Bernd Hitzmann; Jochen Büchs
Journal:  Bioengineering (Basel)       Date:  2022-09-04

4.  Screening of a genome-reduced Corynebacterium glutamicum strain library for improved heterologous cutinase secretion.

Authors:  Johannes Hemmerich; Mohamed Labib; Carmen Steffens; Sebastian J Reich; Marc Weiske; Meike Baumgart; Christian Rückert; Matthias Ruwe; Daniel Siebert; Volker F Wendisch; Jörn Kalinowski; Wolfgang Wiechert; Marco Oldiges
Journal:  Microb Biotechnol       Date:  2020-09-06       Impact factor: 5.813

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.