Literature DB >> 27860161

Closure of very large PDA with pulmonary hypertension: Initial clinical case-series with the new Occlutech® PDA occluder.

Anja Lehner1, Sarah Ulrich1, Christoph M Happel2, Marcus Fischer1, Marinos Kantzis2, Ingram Schulze-Neick1, Nikolaus A Haas1.   

Abstract

OBJECTIVE: We report our recent experience with the new Occlutech® PDA Occluder, which seems suitable especially for closure of large patent ductus arteriosus (PDA) sizes with elevated pulmonary artery pressure (PAH).
BACKGROUND: Although considered a standard procedure in pediatric cath labs, closure of very large PDA (PDA/Aorta ratio > 0.5) and PAH remains a challenge. METHODS/
RESULTS: The Occlutech® PDA occluder was used in eight children and adolescents (age 4-16, median 10.75 years), body weight from 14 to 54 kg (median 21 kg) with very large PDA and PAH: PDA diameter was 5-13 mm (median 10 mm); PAP/Aortic pressure ratio was 0.58-0.96. Sufficient occlusion of the PDA was documented by angiography and/or echocardiography in all cases. Four different device sizes were selected: Minimal diameter 6-14 mm (median 12 mm), length 6.3-16 mm (median 14 mm), aortic disc 13-24 mm (median 20 mm), size at the pulmonary end 8-18 mm (median 15 mm). A balloon test occlusion of the PDA was performed in five patients in order to evaulate the decline of pulmonary artery pressure or to delineate the exact anatomy of the PDA. Before release of the device, a careful "wiggle manoevre" was performed to assess the stability of the implanted device and to proof the inability to embolize to the aorta.
CONCLUSIONS: With the new Occlutech® PDA Occluder closure of very large PDAs and PAH is feasible and efficient. The wider pulmonary artery end of the Occlutech® PDA Occluder offers enhanced stability and reduces the risk of embolization.
© 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  Occlutech® PDA occlude; patent ductus arteriosus; pulmonary arterial hypertension

Mesh:

Year:  2016        PMID: 27860161     DOI: 10.1002/ccd.26856

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  2 in total

1.  Percutaneous closure of patent ductus arteriosus with the Nit-Occlud® patent ductus arteriosus device in 268 consecutive cases.

Authors:  Andrii V Maksymenko; Yulia L Kuzmenko; Arkadii A Dovhaliuk; Oleksandra O Motrechko; Florian E Herrmann; Nikolaus A Haas; Anja Lehner
Journal:  Ann Pediatr Cardiol       Date:  2019 Sep-Dec

Review 2.  The Patent Ductus Arteriosus in Adults with Special Focus on Role of CT.

Authors:  Soo Jeong Lee; Seung Min Yoo; Min Ji Son; Charles S White
Journal:  Diagnostics (Basel)       Date:  2021-12-19
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.